Literature DB >> 11011685

Corneal thickness and corneal endothelium in normotensive subjects with unilateral exfoliation syndrome.

P Puska1, K Vasara, M Harju, K Setälä.   

Abstract

PURPOSE: To examine the central corneal thickness (CCT) and corneal endothelium in both eyes of patients with unilateral exfoliation syndrome (EXS). To determine the effect of CCT on the measurement of intraocular pressure (IOP).
METHODS: In this cross-sectional clinical study, comparisons were made of CCT (Humphrey Ultrasonic Pachometer), corneal endothelial cells (Keeler-Konan contact specular microscope) and IOP (Goldmann applanation tonometer) between the exfoliative (E) and fellow nonexfoliative (NE) eyes in 40 normotensive patients with unilateral EXS. The CCT was used to obtain a corrected value for the IOP.
RESULTS: The E eyes had significantly higher values for CCT (0.528+/-0.030 vs 0.523+/-0.032 mm, P<0.01) and IOP (15.7+/-3.6 vs 14.4+/-2.9 mmHg, P<0.001) than the fellow NE eyes. The paired E and NE eyes did not differ in endothelial cell density (2779+/-540 vs 2870+/-386 cells/mm2), in the coefficient of variation of cell size (0.25+/-0.03 vs 0.26+/-0.03) or in the frequency of hexagonal cells (80.5+/-6.5 vs 82.0+/-5.0%). After correcting IOP for CCT, the E eyes still had significantly higher IOP than the NE eyes (15.1+/-4.4 vs 14.2+/-3.7 mmHg, P<0.05).
CONCLUSION: Normotensive eyes with early EXS did not have quantitative (cell density) or qualitative (variation in cell size, frequency of hexagonal cells) morphological changes in corneal endothelium, but had higher values for IOP and CCT. After correcting IOP for CCT, the E eyes still had significantly higher IOP than the fellow NE eyes.

Entities:  

Mesh:

Year:  2000        PMID: 11011685     DOI: 10.1007/s004170000159

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  17 in total

1.  The effects of corneal parameters on the assessment of endothelial cell density in the elderly eye.

Authors:  A Müller; J P Craig; C N Grupcheva; C N J McGhee
Journal:  Br J Ophthalmol       Date:  2004-03       Impact factor: 4.638

Review 2.  [PEX syndrome. Clinical diagnosis and systemic manifestations].

Authors:  E Scharfenberg; U Schlötzer-Schrehardt
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

3.  Corneal endothelial changes following a single session of selective laser trabeculoplasty for pseudoexfoliative glaucoma.

Authors:  Nurgül Örnek; Kemal Örnek
Journal:  Int Ophthalmol       Date:  2017-10-13       Impact factor: 2.031

4.  Ocular response analyzer to assess corneal biomechanical properties in exfoliation syndrome and exfoliative glaucoma.

Authors:  Ali Bulent Cankaya; Alpaslan Anayol; Dilek Özcelik; Elif Demirdogen; Pelin Yilmazbas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-24       Impact factor: 3.117

5.  Corneal endothelial cell density and morphology in Chinese patients with pseudoexfoliation syndrome.

Authors:  Meng Wang; Wei Sun; Liang Ying; Xiao-Guang Dong
Journal:  Int J Ophthalmol       Date:  2012-04-18       Impact factor: 1.779

6.  Response to the comments of Gatzioufas Z. & Seitz B. on the article entitled: "Ocular response analyser to assess corneal biomechanical properties in exfoliation syndrome and exfoliative glaucoma".

Authors:  Ali Bulent Cankaya; Alpaslan Anayol; Pelin Yilmazbas
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-20       Impact factor: 3.117

7.  Corneal biomechanical properties in exfoliation syndrome and exfoliation glaucoma.

Authors:  Zisis Gatzioufas; Berthold Seitz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-21       Impact factor: 3.117

8.  Does the conjunctivochalasis accompanied by pseudoexfoliation syndrome affect the ocular surface and anterior segment structures?

Authors:  Bediz Özen; Hakan Öztürk
Journal:  Int Ophthalmol       Date:  2022-03-30       Impact factor: 2.029

9.  Evaluation of Optical Low Coherence Reflectometry Parameters in Patients with Exfoliation Syndrome.

Authors:  Emrullah Beyazyıldız; Özlem Beyazyıldız; Süleyman Günaydın; Emrah Kan; Mert Şimşek; Pelin Yılmazbaş; Faruk Öztürk
Journal:  J Ophthalmol       Date:  2015-04-28       Impact factor: 1.909

10.  Central corneal thickness in subjects with glaucoma and in normal individuals (with or without pseudoexfoliation syndrome).

Authors:  Georgios Kitsos; Christos Gartzios; Ioannis Asproudis; Eleni Bagli
Journal:  Clin Ophthalmol       Date:  2009-10-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.