Literature DB >> 10997059

Evaluation of bone strength: correlation between measurements of bone mineral density and drilling force.

F R Ong1, K Bouazza-Marouf.   

Abstract

Bone drilling is a major part of modern orthopaedic surgery which involves the internal fixation of fractured bones. The investigation of bone drilling described in this paper demonstrates the contribution of automation technology towards the study of bone strength. The aim of this preliminary investigation is to establish a relationship between bone drilling forces and measurements of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA). A linear relationship with a high coefficient of correlation has been found between average drilling forces and BMD measurements at both the greater trochanter and the femoral head of porcine femurs when drilling in the anterior-posterior (AP) direction (i.e. the direction of the DXA scan). It has also been found that in the normal drilling direction (i.e. in the cervical axis direction), which is orthogonal to the DXA scanning direction, there are similar trends between the drilling forces and BMD levels in regions where bone density is more consistent (e.g. the femoral head). The findings of this investigation indicate that analysis of bone drilling forces has the potential to provide useful information about the strength of bone.

Entities:  

Mesh:

Year:  2000        PMID: 10997059     DOI: 10.1243/0954411001535426

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  5 in total

1.  Dual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time.

Authors:  Brian B Gilmer; Sarah D Lang
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-09-25

2.  Modulation of osteogenic differentiation by Escherichia coli-derived recombinant bone morphogenetic protein-2.

Authors:  Nam-Hyun Kim; Seon-Kyong Jung; Juno Lee; Pahn-Shick Chang; Seung-Hoon Kang
Journal:  AMB Express       Date:  2022-08-10       Impact factor: 4.126

3.  Relationships between tissue properties and operational parameters of a dental handpiece during simulated cavity preparation.

Authors:  Hongyan Sun; Andrew Lau; Young C Heo; Lianshan Lin; Ralph Delong; Alex Fok
Journal:  J Dent Biomech       Date:  2013-03-25

4.  Human bone morphogenetic protein-2 (hBMP-2) characterization by physical-chemical, immunological and biological assays.

Authors:  Miriam Fussae Suzuki; João Ezequiel Oliveira; Renata Damiani; Eliana Rosa Lima; Kleicy Cavalcante Amaral; Anderson Maikon de Souza Santos; Geraldo Santana Magalhães; Leonardo Perez Faverani; Luis Antonio Violin Dias Pereira; Fabiana Medeiros Silva; Paolo Bartolini
Journal:  AMB Express       Date:  2020-02-17       Impact factor: 3.298

5.  Synthesis of Human Bone Morphogenetic Protein-2 (hBMP-2) in E. coli Periplasmic Space: Its Characterization and Preclinical Testing.

Authors:  João E Oliveira; Miriam F Suzuki; Renata Damiani; Eliana R Lima; Kleicy C Amaral; Anderson M S Santos; Geraldo S Magalhães; Leonardo P Faverani; Luís A V D Pereira; Paolo Bartolini
Journal:  Cells       Date:  2021-12-14       Impact factor: 6.600

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.