Literature DB >> 10993864

Positive geometric vascular remodeling is seen after catheter-based radiation followed by conventional stent implantation but not after radioactive stent implantation.

I P Kay1, M Sabaté, M A Costa, K Kozuma, M Albertal, W J van der Giessen, A J Wardeh, J M Ligthart, V M Coen, P C Levendag, P W Serruys.   

Abstract

BACKGROUND: Recent reports demonstrate that intracoronary radiation affects not only neointimal formation but also vascular remodeling. Radioactive stents and catheter-based techniques deliver radiation in different ways, suggesting that different patterns of remodeling after each technique may be expected. METHODS AND
RESULTS: We analyzed remodeling in 18 patients after conventional stent implantation, 16 patients after low-activity radioactive stent implantation, 16 patients after higher activity radioactive stent implantation, and, finally, 17 patients who underwent catheter-based radiation followed by conventional stent implantation. Intravascular ultrasound with 3D reconstruction was used after stent implantation and at the 6-month follow-up to assess remodeling within the stent margins and at its edges. Preprocedural characteristics were similar between groups. In-stent neointimal hyperplasia (NIH) was inhibited by high-activity radioactive stent implantation (NIH 9.0 mm(3)) and by catheter-based radiation followed by conventional stent implantation (NIH 6.9 mm(3)) compared with low-activity radioactive stent implantation (NIH 21.2 mm(3)) and conventional stent implantation (NIH 20.8 mm(3)) (P:=0.008). No difference in plaque or total vessel volume was seen behind the stent in the conventional, low-activity, or high-activity stent implantation groups. However, significant increases in plaque behind the stent (15%) and in total vessel volume (8%) were seen in the group that underwent catheter-based radiation followed by conventional stent implantation. All 4 groups demonstrated significant late lumen loss at the stent edges; however, edge restenosis was seen only in the group subjected to high-activity stent implantation and appeared to be due to an increase in plaque and, to a lesser degree, to negative remodeling.
CONCLUSIONS: Distinct differences in the patterns of remodeling exist between conventional, radioactive, and catheter-based radiotherapy with stenting.

Entities:  

Mesh:

Year:  2000        PMID: 10993864     DOI: 10.1161/01.cir.102.12.1434

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

Review 1.  What has intravascular ultrasound taught us about plaque biology?

Authors:  S Kinlay
Journal:  Curr Atheroscler Rep       Date:  2001-05       Impact factor: 5.113

2.  Adventitial response to intravascular brachytherapy in a rabbit model of restenosis.

Authors:  Paul Wexberg; Konrad Mück; Ursula Windberger; Susanna Lang; Martin Osranek; Franz Weidinger; Gerald Maurer; Michael Gottsauner-Wolf
Journal:  Wien Klin Wochenschr       Date:  2004-03-31       Impact factor: 1.704

3.  The duration of balloon inflation affects the luminal diameter of coronary segments after bioresorbable vascular scaffolds deployment.

Authors:  Sabato Sorrentino; Salvatore De Rosa; Giuseppe Ambrosio; Annalisa Mongiardo; Carmen Spaccarotella; Alberto Polimeni; Jolanda Sabatino; Daniele Torella; Gianluca Caiazzo; Ciro Indolfi
Journal:  BMC Cardiovasc Disord       Date:  2015-12-11       Impact factor: 2.298

4.  Two decades after coronary radiation therapy: A single center longitudinal clinical study.

Authors:  Sumant P Radhoe; Anne-Sophie Schuurman; Jurgen M Ligthart; Karen Witberg; Peter P T de Jaegere; Ron T van Domburg; Evelyn Regar
Journal:  Catheter Cardiovasc Interv       Date:  2019-12-02       Impact factor: 2.692

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.