Literature DB >> 10984695

A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty.

N J Hallab1, K Mikecz, J J Jacobs.   

Abstract

The determination of biocompatibility has been dominated historically by the characterization of candidate materials based upon the observation of adverse host responses. However, some adverse responses are subtle in clinical settings and continue to foster debate and investigation. One of these responses is "metal allergy" or hypersensitivity to metallic biomaterials. Current methods used to diagnose hypersensitivity reactions, such as dermal patch testing and migration inhibition assays, are not well accepted in orthopedic practice as a means for the characterization of hypersensitivity to metallic joint-replacement components. An increasing need to resolve whether metal sensitivity may be a significant and/or predisposing factor for eliciting an over-aggressive immune response in patients with metallic implant components requires improved and standardized widespread study. Here we present three in vitro methodologies: (1) a proliferation assay, (2) cytokine analysis using ELISA, and (3) a migration inhibition assay. When in conjunction with one another, these assays may be used to more comprehensively quantify metal-induced hypersensitivity responses. Therefore, these methodologies are detailed with the intent of facilitating multi-center large-scale studies. In the following cases, a multi-assay approach for measuring the prevalence of delayed-type hypersensitivity in orthopedic patients shows the propensity to yield a more comprehensive and, therefore, more conclusive determination than currently employed patch testing or single assay techniques. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10984695     DOI: 10.1002/1097-4636(200009)53:5<480::aid-jbm6>3.0.co;2-b

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  13 in total

1.  Revision for taper corrosion at the neck-body junction following total hip arthroplasty: pearls and pitfalls.

Authors:  Mitchell C Weiser; Darwin D Chen
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

2.  Factors to consider in joint prosthesis systems.

Authors:  Larry M Wolford
Journal:  Proc (Bayl Univ Med Cent)       Date:  2006-07

Review 3.  The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

Authors:  William T Long
Journal:  Iowa Orthop J       Date:  2005

4.  Postoperative spinal infection mimicking systemic vasculitis with titanium-spinal implants.

Authors:  Vasileios I Sakellariou; Erato Atsali; Konstantinos Starantzis; Chrysanthi Batistaki; Triantafyllia Brozou; Panayiotis Pantos; Konstantinos Stathopoulos; Konstantinos Soultanis
Journal:  Scoliosis       Date:  2011-09-13

5.  Total knee arthroplasty in patients with hypersensitivity to metals.

Authors:  Massimo Innocenti; Christian Carulli; Fabrizio Matassi; Anna Maria Carossino; Maria Luisa Brandi; Roberto Civinini
Journal:  Int Orthop       Date:  2014-01-04       Impact factor: 3.075

6.  [Sensitivity to constituents of bone cement in a patient with joint prosthesis].

Authors:  D Richter-Hintz; J Rieker; L Rauch; B Homey
Journal:  Hautarzt       Date:  2004-10       Impact factor: 0.751

7.  Do patients with a failed metal-on-metal hip implant with a pseudotumor present differences in their peripheral blood lymphocyte subpopulations?

Authors:  Isabelle Catelas; Eric A Lehoux; Ian Hurda; Stephen J Baskey; Luca Gala; Ryan Foster; Paul R Kim; Paul E Beaulé
Journal:  Clin Orthop Relat Res       Date:  2015-09-01       Impact factor: 4.176

8.  [In vitro analysis of the impact of metal ions on human lymphocyte cultures].

Authors:  S Hagmann; J Kirsch; J P Kretzer; B Moradi
Journal:  Orthopade       Date:  2013-08       Impact factor: 1.087

9.  Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant.

Authors:  Csaba Vermes; József Kuzsner; Tamás Bárdos; Péter Than
Journal:  J Orthop Surg Res       Date:  2013-05-16       Impact factor: 2.359

10.  Metal-on-Metal Hip Retrieval Analysis: A Case Report.

Authors:  Thomas B Pace; Kara A Rusaw; Lawrence J Minette; Brayton R Shirley; Rebecca G Snider; John D Desjardins
Journal:  Case Rep Orthop       Date:  2013-06-09
View more