Literature DB >> 10984242

Segmentation of carotid artery in ultrasound images: method development and evaluation technique.

F Mao1, J Gill, D Downey, A Fenster.   

Abstract

Segmentation of carotid artery lumen in two-dimensional and three-dimensional ultrasonography is an important step in computerized evaluation of arterial disease severity and in finding vulnerable atherosclerotic plaques susceptible to rupture causing stroke. Because of the complexity of anatomical structures, noise as well as the requirement of accurate segmentation, interactions are necessary between observers and the computer segmentation process. In this paper a segmentation process is described based on the deformable model method with only one seed point to guide the initialization of the deformable model for each lumen cross section. With one seed, the initial contour of the deformable model is generated using the entropy map of the original image and mathematical morphology operations. The deformable model is driven to fit the lumen contour by an internal force and an external force that are calculated, respectively, with geometrical properties of deformed contour and with the image gray level features. The evaluation methodology using distance-based and area-based metrics is introduced in this paper. A contour probability distribution (CPD) method for calculating distance-based metrics is introduced. The CPD is obtained by generating contours of the lumen using a set of possible seed locations. The mean contour can be compared to a manual outlined contour to provide accuracy metrics. The variance computed from the CPD can provide metrics of local and global variability. These metrics provide a complete performance evaluation of an interactive segmentation algorithm and a means for comparing different algorithm settings.

Entities:  

Mesh:

Year:  2000        PMID: 10984242     DOI: 10.1118/1.1287111

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Snakes based segmentation of the common carotid artery intima media.

Authors:  C P Loizou; C S Pattichis; M Pantziaris; T Tyllis; A Nicolaides
Journal:  Med Biol Eng Comput       Date:  2007-01-03       Impact factor: 2.602

2.  Detection of the intima and media layer thickness of ultrasound common carotid artery image using efficient active contour segmentation technique.

Authors:  N Santhiyakumari; P Rajendran; M Madheswaran; S Suresh
Journal:  Med Biol Eng Comput       Date:  2011-07-20       Impact factor: 2.602

3.  Evaluation of carotid intima media thickness measurement from ultrasound images.

Authors:  B Smitha; Dhanraj Yadav; Paul K Joseph
Journal:  Med Biol Eng Comput       Date:  2022-01-06       Impact factor: 2.602

4.  Fully automated common carotid artery and internal jugular vein identification and tracking using B-mode ultrasound.

Authors:  David C Wang; Roberta Klatzky; Bing Wu; Gregory Weller; Allan R Sampson; George D Stetten
Journal:  IEEE Trans Biomed Eng       Date:  2009-03-04       Impact factor: 4.538

5.  A review of ultrasound common carotid artery image and video segmentation techniques.

Authors:  Christos P Loizou
Journal:  Med Biol Eng Comput       Date:  2014-10-05       Impact factor: 2.602

6.  Ultrasound common carotid artery segmentation based on active shape model.

Authors:  Xin Yang; Jiaoying Jin; Mengling Xu; Huihui Wu; Wanji He; Ming Yuchi; Mingyue Ding
Journal:  Comput Math Methods Med       Date:  2013-03-06       Impact factor: 2.238

7.  Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.

Authors:  Joerik de Ruijter; Marc van Sambeek; Frans van de Vosse; Richard Lopata
Journal:  Med Phys       Date:  2020-01-03       Impact factor: 4.071

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.