Literature DB >> 19272982

Fully automated common carotid artery and internal jugular vein identification and tracking using B-mode ultrasound.

David C Wang1, Roberta Klatzky, Bing Wu, Gregory Weller, Allan R Sampson, George D Stetten.   

Abstract

We describe a fully automated ultrasound analysis system that tracks and identifies the common carotid artery (CCA) and the internal jugular vein (IJV). Our goal is to prevent inadvertent damage to the CCA when targeting the IJV for catheterization. The automated system starts by identifying and fitting ellipses to all the regions that look like major arteries or veins throughout each B-mode ultrasound image frame. The spokes ellipse algorithm described in this paper tracks these putative vessels and calculates their characteristics, which are then weighted and summed to identify the vessels. The optimum subset of characteristics and their weights were determined from a training set of 38 subjects, whose necks were scanned with a portable 10 MHz ultrasound system at 10 frames per second. Stepwise linear discriminant analysis (LDA) narrowed the characteristics to the five that best distinguish between the CCA and IJV. A paired version of Fisher's LDA was used to calculate the weights for each of the five parameters. Leave-one-out validation studies showed that the system could track and identify the CCA and IJV with 100% accuracy in this dataset.

Entities:  

Mesh:

Year:  2009        PMID: 19272982      PMCID: PMC2873619          DOI: 10.1109/TBME.2009.2015576

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  Overlaying ultrasonographic images on direct vision.

Authors:  G D Stetten; V S Chib
Journal:  J Ultrasound Med       Date:  2001-03       Impact factor: 2.153

2.  An algorithm for automatic needle localization in ultrasound-guided breast biopsies.

Authors:  K J Draper; C C Blake; L Gowman; D B Downey; A Fenster
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

3.  Prostate boundary segmentation from 2D ultrasound images.

Authors:  H M Ladak; F Mao; Y Wang; D B Downey; D A Steinman; A Fenster
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

4.  Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography.

Authors:  C A Troianos; R J Kuwik; J R Pasqual; A J Lim; D P Odasso
Journal:  Anesthesiology       Date:  1996-07       Impact factor: 7.892

Review 5.  Ultrasound image segmentation: a survey.

Authors:  J Alison Noble; Djamal Boukerroui
Journal:  IEEE Trans Med Imaging       Date:  2006-08       Impact factor: 10.048

6.  Carotid artery and jugular vein tracking and differentiation using spatiotemporal analysis.

Authors:  David Wang; Roberta Klatzky; Nikhil Amesur; George Stetten
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

7.  Real-time vessel segmentation and tracking for ultrasound imaging applications.

Authors:  Julian Guerrero; Septimiu E Salcudean; James A McEwen; Bassam A Masri; Savvakis Nicolaou
Journal:  IEEE Trans Med Imaging       Date:  2007-08       Impact factor: 10.048

8.  Transesophageal echocardiographic identification of a retrograde dissection of the ascending aorta caused by inadvertent cannulation of the common carotid artery.

Authors:  R M Applebaum; M A Adelman; M S Kanschuger; G Jacobowitz; I Kronzon
Journal:  J Am Soc Echocardiogr       Date:  1997-09       Impact factor: 5.251

9.  Pulmonary artery catheterisation. An assessment of risks and benefits in 220 surgical patients.

Authors:  M J Davies; K D Cronin; C M Domaingue
Journal:  Anaesth Intensive Care       Date:  1982-02       Impact factor: 1.669

10.  Cerebral infarct following central venous cannulation.

Authors:  N A Zaidi; M Khan; H I Naqvi; R S Kamal
Journal:  Anaesthesia       Date:  1998-02       Impact factor: 6.955

View more
  9 in total

Review 1.  Assistive technology for ultrasound-guided central venous catheter placement.

Authors:  Mohammad Ikhsan; Kok Kiong Tan; Andi Sudjana Putra
Journal:  J Med Ultrason (2001)       Date:  2017-04-19       Impact factor: 1.314

2.  Determination of vessel cross-sectional area by thresholding in Radon space.

Authors:  Yu-Rong Gao; Patrick J Drew
Journal:  J Cereb Blood Flow Metab       Date:  2014-04-16       Impact factor: 6.200

3.  Estimating 3D lumen centerlines of carotid arteries in free-hand acquisition ultrasound.

Authors:  Diego D B Carvalho; Stefan Klein; Zeynettin Akkus; Gerrit L ten Kate; Arend F L Schinkel; Johan G Bosch; Aad van der Lugt; Wiro J Niessen
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-06-29       Impact factor: 2.924

4.  Asymmetric pulsation of rat carotid artery bifurcation in three-dimension observed by ultrasound imaging.

Authors:  Changzhu Jin; Kweon-Ho Nam; Dong-Guk Paeng
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-04       Impact factor: 2.357

5.  In vivo identification of arteries and veins using two-photon excitation elastin autofluorescence.

Authors:  Hui Li; Meng Yan; Jia Yu; Qiang Xu; Xianyuan Xia; Jiuling Liao; Wei Zheng
Journal:  J Anat       Date:  2019-08-29       Impact factor: 2.610

6.  Quantitative ColourDopplerSonography evaluation of cerebral venous outflow: a comparative study between patients with multiple sclerosis and controls.

Authors:  Lucia Monti; Elisabetta Menci; Monica Ulivelli; Alfonso Cerase; Sabina Bartalini; Pietro Piu; Nicola Marotti; Sara Leonini; Paolo Galluzzi; Daniele G Romano; Alfredo E Casasco; Carlo Venturi
Journal:  PLoS One       Date:  2011-09-22       Impact factor: 3.240

7.  Variations in the anatomical relationship between the common carotid artery and the internal jugular vein: an ultrasonographic study.

Authors:  Mauricio Umaña; Alberto García; Luis Bustamante; José Luis Castillo; Juan Sebastián Martínez
Journal:  Colomb Med (Cali)       Date:  2015-06-30

8.  Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.

Authors:  Joerik de Ruijter; Marc van Sambeek; Frans van de Vosse; Richard Lopata
Journal:  Med Phys       Date:  2020-01-03       Impact factor: 4.071

9.  AI-Enabled, Ultrasound-Guided Handheld Robotic Device for Femoral Vascular Access.

Authors:  Laura J Brattain; Theodore T Pierce; Lars A Gjesteby; Matthew R Johnson; Nancy D DeLosa; Joshua S Werblin; Jay F Gupta; Arinc Ozturk; Xiaohong Wang; Qian Li; Brian A Telfer; Anthony E Samir
Journal:  Biosensors (Basel)       Date:  2021-12-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.