Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes.

J Allen1, A Murray.   

Abstract

The characteristics of the photoplethysmography (PPG) pulse signal are body site specific, with pulses from the various peripheral sites showing differences in pulse transit time, strength and shape, and variation of each over time. The aim of this study was to determine the similarity in the right-left pulse characteristics for a group of normal subjects with pulses obtained simultaneously from six peripheral sites (cars, thumbs and big toes). A multi-site photoplethysmography pulse measurement and analysis system is described and comprised six sets of pulse probes and amplifiers, arranged and electronically matched in pairs for the right and left side comparisons. Two sets of data were collected: firstly a set of validation data to test the electronic matching of right left channels, and secondly a set of physiological data for pulses from 40 normal subjects. The right-to-left side similarity in pulse waveform shape at the three segmental levels (ears, thumbs and toes) was assessed using two types of analysis: root mean square error (RMSE) providing a measure of differences, and cross correlation analysis providing a measure of the degree of similarity. Very low levels of RMSE and correlation coefficients close to unity were obtained for the system validation data, demonstrating good right-left channel matching. The RMSE was an order of magnitude lower than that calculated for the normative physiological data, where median RMSE levels were between 0.053 and 0.060 relative to a peak-to-peak pulse amplitude of unity. The median correlation coefficients were greater than 0.98 for all three segmental levels studied, with the maximum values approaching those of the validation data. We have shown that pulses from the right and left sides of normal subjects are highly correlated at each segmental level. We have obtained a normative range of pulse data, with which specific (vascular) patient groups can be compared.

Entities:  

Mesh:

Year:  2000        PMID: 10984205     DOI: 10.1088/0967-3334/21/3/303

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  19 in total

1.  Influence of thoracic sympathectomy on cardiac induced oscillations in tissue blood volume.

Authors:  M Nitzan; A Babchenko; D Shemesh; J Alberton
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal.

Authors:  B Khanokh; Y Slovik; D Landau; M Nitzan
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

Review 3.  Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.

Authors:  Yu Sun; Nitish Thakor
Journal:  IEEE Trans Biomed Eng       Date:  2015-09-15       Impact factor: 4.538

Review 4.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

5.  Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale.

Authors:  Shing-Hong Liu; Bing-Hao Zhang; Wenxi Chen; Chun-Hung Su; Chiun-Li Chin
Journal:  Nutrients       Date:  2022-06-20       Impact factor: 6.706

6.  Non-invasive estimation of systolic blood pressure and diastolic blood pressure using photoplethysmograph components.

Authors:  Incheol Jeong; Sukhwan Jun; Daeja Um; Joonghwan Oh; Hyungro Yoon
Journal:  Yonsei Med J       Date:  2010-05       Impact factor: 2.759

7.  Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe.

Authors:  Seyedmohsen Dehghanojamahalleh; Mehmet Kaya
Journal:  IEEE J Transl Eng Health Med       Date:  2019-08-30       Impact factor: 3.316

8.  Quantification the effect of ageing on characteristics of the photoplethysmogram using an optimized windkessel model.

Authors:  H Doostdar; Ma Khalilzadeh
Journal:  J Biomed Phys Eng       Date:  2014-09-01

9.  Toward a Smartphone Application for Estimation of Pulse Transit Time.

Authors:  He Liu; Kamen Ivanov; Yadong Wang; Lei Wang
Journal:  Sensors (Basel)       Date:  2015-10-27       Impact factor: 3.576

10.  Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents.

Authors:  Takehiro Yamakoshi; Jihyoung Lee; Kenta Matsumura; Yasuhiro Yamakoshi; Peter Rolfe; Daiki Kiyohara; Ken-ichi Yamakoshi
Journal:  PLoS One       Date:  2015-12-04       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.