Literature DB >> 10982948

Assessing the implant/bone interface by using natural frequency analysis.

H M Huang1, L C Pan, S Y Lee, C L Chiu, K H Fan, K N Ho.   

Abstract

OBJECTIVE: A number of techniques have been proposed for detecting the stability of dental implants. However, the clinical applicability of those methods is still limited. The purpose of this study was to evaluate a new innovative, noninvasive, minimum-contact method for the stability assessment of dental implants. STUDY
DESIGN: Natural frequency is a physical property of a structure, which is strongly related to its boundary conditions. In this study, a modal testing technique was carried out to measure the natural frequency of dental implants. The implants were fixed by a metal clamp stand and were excited to vibrate by an impulse hammer. A noncontact piezoelectric microphone then acoustically acquired the vibration responses of the implants. Natural frequencies of the tested implants were recorded under various clamping forces and clamping levels.
RESULTS: Natural frequencies of the tested implants were concentrated from 8 to 19 kHz under different boundary conditions. On the other hand, the natural frequency values decreased when boundary levels and boundary force were reduced. Linear relationships (P <.005) were found between response frequencies and the degree of implant stability.
CONCLUSIONS: Our results show that the boundary status of an implant can be monitored by detecting its natural frequency. A noncontact transducer used in this study can also serve as a useful tool for future clinical investigations.

Mesh:

Substances:

Year:  2000        PMID: 10982948     DOI: 10.1067/moe.2000.108918

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  10 in total

1.  Towards the limit of quantifying low-amplitude strains on bone and in coagulum around immediately loaded oral implants in extraction sockets.

Authors:  Murat Cavit Cehreli; Ayhan Comert; Murat Akkocaoglu; Ibrahim Tekdemir; Kivanc Akca
Journal:  Med Biol Eng Comput       Date:  2006-03       Impact factor: 2.602

2.  Assessment of implant stability following sinus lift procedures with different grafting materials.

Authors:  Damir Jelušić; Ivan Puhar; Darije Plančak
Journal:  Acta Stomatol Croat       Date:  2014-03

3.  The effects of elevated hemoglobin A(1c) in patients with type 2 diabetes mellitus on dental implants: Survival and stability at one year.

Authors:  Thomas W Oates; Patrick Galloway; Peggy Alexander; Adriana Vargas Green; Guy Huynh-Ba; Jocelyn Feine; C Alex McMahan
Journal:  J Am Dent Assoc       Date:  2014-12       Impact factor: 3.634

4.  The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment.

Authors:  Pratik Nag; Bhaskar Borgohain; Kashif Akhtar Ahmed; Pranjal Phukan; Neeraj Kumar; Alireza Borjali; Kartik Mangudi Varadarajan; Souptick Chanda
Journal:  Ann Biomed Eng       Date:  2022-07-12       Impact factor: 4.219

5.  A comparative study on the accuracy of the devices for measuring the implant stability.

Authors:  In-Ho Cho; Young-Il Lee; Young-Mi Kim
Journal:  J Adv Prosthodont       Date:  2009-11-30       Impact factor: 1.904

6.  A Comparision of Two Types of Decalcified Freeze-Dried Bone Allograft in Treatment of Dehiscence Defects around Implants in Dogs.

Authors:  Ahmad Moghareh Abed; Rasool Heidari Pestekan; Jaber Yaghini; Seyed Mohammad Razavi; Mohammad Tavakoli; Mohammad Amjadi
Journal:  Dent Res J (Isfahan)       Date:  2011

7.  Evaluation of stability changes in tapered and parallel wall implants: a human clinical trial.

Authors:  Ar Rokn; Aar Rasouli Ghahroudi; A Mesgarzadeh; Aa Miremadi; S Yaghoobi
Journal:  J Dent (Tehran)       Date:  2011-12-20

8.  Retrospective clinical study of an implant with a sandblasted, large-grit, acid-etched surface and internal connection: analysis of short-term success rate and marginal bone loss.

Authors:  Jae-Wang Lee; Jun Hyeong An; Sang-Hoon Park; Jong-Hyon Chong; Gwang-Seok Kim; JeongJoon Han; Seunggon Jung; Min-Suk Kook; Hee-Kyun Oh; Sun-Youl Ryu; Hong-Ju Park
Journal:  Maxillofac Plast Reconstr Surg       Date:  2016-11-05

9.  Enhanced Osseointegration of a Modified Titanium Implant with Bound Phospho-Threonine: A Preliminary In Vivo Study.

Authors:  Yohei Okazaki; Kazuya Doi; Yoshifumi Oki; Reiko Kobatake; Yasuhiko Abe; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2017-05-25

10.  Development of implant/interconnected porous hydroxyapatite complex as new concept graft material.

Authors:  Kazuya Doi; Hiroshi Oue; Koji Morita; Shiho Kajihara; Takayasu Kubo; Katsunori Koretake; Vittoria Perrotti; Giovanna Iezzi; Adriano Piattelli; Yasumasa Akagawa
Journal:  PLoS One       Date:  2012-11-09       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.