Literature DB >> 10982924

Effects of a mandibular repositioner on obstructive sleep apnea.

Y Liu1, X Zeng, M Fu, X Huang, A A Lowe.   

Abstract

The purpose of this study was to investigate the effects of a mandibular repositioner on airway, sleep, and respiratory variables in patients with obstructive sleep apnea. Twenty-two patients selected for this study were confirmed with a diagnosis of obstructive sleep apnea based on initial nocturnal polysomnography. The patients were fitted with a mandibular repositioner designed to hold the mandible anteroinferiorly. Six months later, an outcome polysomnographic study was undertaken for each patient with the appliance in place. Lateral cephalometric radiographs in the upright position were also obtained before and after 6 months of treatment. The respiratory disturbance index decreased in 21 of the 22 patients with the appliance in place. The mean respiratory disturbance index of the 22 patients decreased significantly from 40.3 to 11.7 events per hour (P <.01). Some 59.1% of subjects were considered a treatment success with follow-up respiratory disturbance index < 10 events per hour. The mean minimum blood oxygen saturation level during sleep also improved significantly from 73.4% to 81.3% (P <. 01). The mandibular repositioner was constructed to position the mandible at 75% of the maximal mandibular advancement and with a 7 mm opening between the upper and lower incisors, and no aberrant effect on temporomandibular joint was noted. The retropalatal airway space increased and the cross-sectional area of the soft palate and the vertical distance of the hyoid bone to the mandibular plane decreased significantly. The tongue posture became significantly flatter. A significant linear correlation was found between the reduction in apnea index and specific craniofacial skeletal structures (length of anterior cranial base, mandibular plane angle, and upper to lower facial height ratios, P <.05). Subjects with a smaller reduction in apnea index tended to have shorter anterior cranial bases, steeper mandibular planes, and smaller upper to lower facial height ratios. We conclude that a mandibular repositioner may be an effective treatment alternative for obstructive sleep apnea and that a reduction in the frequency of apneic episodes is mainly attributed to the effects of the appliance on oropharyngeal structures.

Entities:  

Mesh:

Year:  2000        PMID: 10982924     DOI: 10.1067/mod.2000.104831

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  19 in total

1.  Cephalometry and prediction of oral appliance treatment outcome.

Authors:  Andrew Tze Ming Ng; M Ali Darendeliler; Peter Petocz; Peter A Cistulli
Journal:  Sleep Breath       Date:  2011-03-19       Impact factor: 2.816

Review 2.  Oral appliances for obstructive sleep apnoea.

Authors:  J Lim; T J Lasserson; J Fleetham; J Wright
Journal:  Cochrane Database Syst Rev       Date:  2006-01-25

3.  Effects of varying mandibular protrusion and degrees of vertical opening on upper airway dimensions in apneic dentate subjects.

Authors:  B Piskin; O Karakoc; H Genc; S Akay; C Sipahi; M Erdem; B Karaman; S Gorgulu; S Yetkin; S Ayyildiz
Journal:  J Orofac Orthop       Date:  2015-01-22       Impact factor: 1.938

4.  Effect of retraction of anterior teeth on pharyngeal airway and hyoid bone position in Class I bimaxillary dentoalveolar protrusion.

Authors:  S Bhatia; B Jayan; S S Chopra
Journal:  Med J Armed Forces India       Date:  2016-10-17

Review 5.  Anatomically Based Outcome Predictors of Treatment for Obstructive Sleep Apnea with Intraoral Splint Devices: A Systematic Review of Cephalometric Studies.

Authors:  Luca Guarda-Nardini; Daniele Manfredini; Marta Mion; Gary Heir; Rosario Marchese-Ragona
Journal:  J Clin Sleep Med       Date:  2015-11-15       Impact factor: 4.062

6.  [Tongue fixation system for therapy of sleeping disorders. A feasibility study].

Authors:  C Punke; C Schöntag; B Hortian; D Behrend; V Hingst; H von Schwanewede; H W Pau
Journal:  HNO       Date:  2010-12       Impact factor: 1.284

7.  Prospective evaluation of an oral appliance in the treatment of obstructive sleep apnea syndrome.

Authors:  J Blanco; C Zamarrón; M T Abeleira Pazos; C Lamela; D Suarez Quintanilla
Journal:  Sleep Breath       Date:  2005-03       Impact factor: 2.816

8.  Is adjustability advantageous in mandibular advancement appliances in the treatment of sleep-disordered breathing?

Authors:  P T George
Journal:  Sleep Breath       Date:  2001-09       Impact factor: 2.816

9.  The efficacy of a mandibular advancement splint in relation to cephalometric variables.

Authors:  Margot A Skinner; Christopher J Robertson; Ruth N Kingshott; David R Jones; D Robin Taylor
Journal:  Sleep Breath       Date:  2002-09       Impact factor: 2.816

10.  A Comparison of Different Success Definitions in Non-Continuous Positive Airway Pressure Treatment for Obstructive Sleep Apnea Using Cardiopulmonary Coupling.

Authors:  Woo Hyun Lee; Seung-No Hong; Hong Joong Kim; Chae-Seo Rhee; Chul Hee Lee; In-Young Yoon; Jeong-Whun Kim
Journal:  J Clin Sleep Med       Date:  2016-01       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.