Literature DB >> 10972328

Affine adaptive filtering of CT data.

C F Westin1, J Richolt, V Moharir, R Kikinis.   

Abstract

A novel method for resampling and enhancing image data using multidimensional adaptive filters is presented. The underlying issue that this paper addresses is segmentation of image structures that are close in size to the voxel geometry. Adaptive filtering is used to reduce both the effects of partial volume averaging by resampling the data to a lattice with higher sample density and to reduce the image noise level. Resampling is achieved by constructing filter sets that have subpixel offsets relative to the original sampling lattice. The filters are also frequency corrected for ansisotropic voxel dimensions. The shift and the voxel dimensions are described by an affine transform and provides a model for tuning the filter frequency functions. The method has been evaluated on CT data where the voxels are in general non cubic. The in-plane resolution in CT image volumes is often higher by a factor of 3-10 than the through-plane resolution. The method clearly shows an improvement over conventional resampling techniques such as cubic spline interpolation and sinc interpolation.

Mesh:

Year:  2000        PMID: 10972328     DOI: 10.1016/s1361-8415(00)00011-6

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  5 in total

1.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Detection of point landmarks in multidimensional tensor data.

Authors:  J Ruiz-Alzola; R Kikinis; C-F Westin
Journal:  Signal Processing       Date:  2001-10       Impact factor: 4.662

3.  Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

Authors:  Ulrich Baum; Katharina Anders; Gregor Steinbichler; Michael Lell; Holger Greess; Thomas Riedel; Marc Kachelriess; Willi A Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2004-08-24       Impact factor: 5.315

4.  Radiation dose reduction in hepatic multidetector computed tomography with a novel adaptive noise reduction filter.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Taiga Goto; Yoshiharu Nakayama; Masamitchi Shimamura; Kumiko Hiraishi; Shinichi Hori; Yasuyuki Yamashita
Journal:  Radiat Med       Date:  2008-04

5.  Non-rigid registration of a 3D ultrasound and a MR image data set of the female pelvic floor using a biomechanical model.

Authors:  Janko F Verhey; Josef Wisser; Simon K Warfield; Jan Rexilius; Ron Kikinis
Journal:  Biomed Eng Online       Date:  2005-03-18       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.