Literature DB >> 10966136

In-vivo measurements of wall shear stress in human coronary arteries.

P A Doriot1, P A Dorsaz, L Dorsaz, E De Benedetti, P Chatelain, P Delafontaine.   

Abstract

BACKGROUND: Wall shear stress (WSS) is closely associated with arteriosclerosis. WSS values for various vessels and species are available, but fully in-vivo measurements in human coronary arteries have not yet been reported.
OBJECTIVE: To measure WSS in undiseased coronary arteries of adult patients at rest.
METHODS: We recorded the temporal average value (APV) of the instantaneous maximal blood velocity in the three vessel segments of angiographically normal coronary artery bifurcations in 21 patients undergoing cardiac catheterization to treat various diseases by means of a 0.036 cm Doppler wire (FloWire). In total, 36 bifurcations were examined. The 36 x 3 cross-sectional areas (CSA) were determined by means of a three-dimensional angiographic technique. The three flows, Q1 (inflow), Q2, and Q3 of each bifurcation were calculated according to Q=0.5 x APV x CSA. For each segment, WSS was calculated as WSS=32 eta Q/(pi D3) (where blood viscosity eta=3.5 mPa s and D is vessel diameter). Only the 54 WSS values obtained from the 18 flow triplets which satisfied the equation Q1/(Q2+Q3)=1 better than did the 18 other ones were retained.
RESULTS: The 54 WSS values ranged from 0.33 to 1.24 Pa (mean 0.68 Pa, SEM, 0.027 Pa). They did not depend significantly on Q (r=0.07; P=0.60) and the CSA (r=0.24, P=0.08) but the second relationship approached significance.
CONCLUSION: The obtained mean WSS value (0.68 Pa) is half the value predicted for coronary arteries from optimality principles. It is also smaller than many values reported for human carotid, renal, and femoral arteries.

Entities:  

Mesh:

Year:  2000        PMID: 10966136     DOI: 10.1097/00019501-200009000-00008

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  23 in total

1.  Vascular endoluminal delivery of mesenchymal stem cells using acoustic radiation force.

Authors:  Catalin Toma; Andrew Fisher; Jianjun Wang; Xucai Chen; Michelle Grata; Jonathan Leeman; Brion Winston; Mehmet Kaya; Huili Fu; Linda Lavery; David Fischer; William R Wagner; Flordeliza S Villanueva
Journal:  Tissue Eng Part A       Date:  2011-02-27       Impact factor: 3.845

2.  The stentable in vitro artery: an instrumented platform for endovascular device development and optimization.

Authors:  Elizabeth E Antoine; François P Cornat; Abdul I Barakat
Journal:  J R Soc Interface       Date:  2016-12       Impact factor: 4.118

3.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models.

Authors:  Claudio Chiastra; Stefano Morlacchi; Diego Gallo; Umberto Morbiducci; Rubén Cárdenes; Ignacio Larrabide; Francesco Migliavacca
Journal:  J R Soc Interface       Date:  2013-05-15       Impact factor: 4.118

4.  Acoustic radiation force for vascular cell therapy: in vitro validation.

Authors:  Mehmet Kaya; Catalin Toma; Jianjun Wang; Michelle Grata; Huili Fu; Flordeliza S Villanueva; Xucai Chen
Journal:  Ultrasound Med Biol       Date:  2012-09-10       Impact factor: 2.998

Review 5.  Changes in cellular mechanical properties during onset or progression of colorectal cancer.

Authors:  Gabriele Ciasca; Massimiliano Papi; Eleonora Minelli; Valentina Palmieri; Marco De Spirito
Journal:  World J Gastroenterol       Date:  2016-08-28       Impact factor: 5.742

6.  3D fusion of intravascular ultrasound and coronary computed tomography for in-vivo wall shear stress analysis: a feasibility study.

Authors:  Alina G van der Giessen; Michiel Schaap; Frank J H Gijsen; Harald C Groen; Theo van Walsum; Nico R Mollet; Jouke Dijkstra; Frans N van de Vosse; Wiro J Niessen; Pim J de Feyter; Antonius F W van der Steen; Jolanda J Wentzel
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-28       Impact factor: 2.357

7.  Wall shear stress as measured in vivo: consequences for the design of the arterial system.

Authors:  Robert S Reneman; Arnold P G Hoeks
Journal:  Med Biol Eng Comput       Date:  2008-05       Impact factor: 2.602

8.  Vascular deposition patterns for nanoparticles in an inflamed patient-specific arterial tree.

Authors:  Shaolie S Hossain; Thomas J R Hughes; Paolo Decuzzi
Journal:  Biomech Model Mechanobiol       Date:  2013-08-14

9.  Endothelial Cell Biomechanical Responses are Dependent on Both Fluid Shear Stress and Tensile Strain.

Authors:  Daphne Meza; Bryan Musmacker; Elisabeth Steadman; Thomas Stransky; David A Rubenstein; Wei Yin
Journal:  Cell Mol Bioeng       Date:  2019-07-09       Impact factor: 2.321

10.  Adaptation of endothelial cells to physiologically-modeled, variable shear stress.

Authors:  Joseph S Uzarski; Edward W Scott; Peter S McFetridge
Journal:  PLoS One       Date:  2013-02-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.