Screening for amblyopia in preverbal children with photoscreening photographs: II. Sensitivity and specificity of the MTI photoscreener.

P Y Tong1, R E Bassin, E Enke-Miyazaki, J P Macke, J M Tielsch, D R Stager, G R Beauchamp, M M Parks.   

Abstract

OBJECTIVE: To determine the sensitivity and specificity of vision screening using the Medical Technology and Innovations (MTI), Inc., PhotoScreener.
DESIGN: Cross-sectional study. PARTICIPANTS AND TESTING: Three hundred ninety-two children less than 4 years of age received a complete ophthalmologic examination and were photographed using the MTI PhotoScreener. One hundred three children had normal examinations, and the remaining 284 children had conditions of interest for pediatric screening: ptosis, media opacity, refractive error, or strabismus. Five children were excluded. MAIN OUTCOME MEASURES: The grading of the photographs by the manufacturer's representative was compared with the results of the ophthalmologic examinations. Sensitivity and specificity of vision screening were determined.
RESULTS: The analysis of all informative photographs resulted in a sensitivity of 65% and a specificity of 87%. The sensitivity of detection for children with some forms of strabismus was high, up to 95% for esotropia of 10Delta or more. Sensitivities for the detection of ptosis, media opacity, and refractive error were poor in patients where strabismus was not also present.
CONCLUSIONS: The MTI PhotoScreener may play a role in preverbal vision screening; identification of two of three children with amblyopiogenic factors before age 4 would be an exciting advance in public health. However, improvement in the ability to identify children with media opacity and refractive error is necessary. Improvements may be possible with modifications of the examination failure and photograph grading criteria.

Entities:  

Mesh:

Year:  2000        PMID: 10964818     DOI: 10.1016/s0161-6420(00)00293-1

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor function.

Authors:  O A Hunt; J S Wolffsohn; B Gilmartin
Journal:  Br J Ophthalmol       Date:  2003-12       Impact factor: 4.638

2.  Screening for visual impairment in children younger than age 5 years: recommendation statement.

Authors: 
Journal:  Ann Fam Med       Date:  2004 May-Jun       Impact factor: 5.166

3.  [Possibilities and limitations of amblyopia screening with auto-refractometers].

Authors:  O Ehrt
Journal:  Ophthalmologe       Date:  2016-04       Impact factor: 1.059

4.  Utilizing minicomputer technology for low-cost photorefraction: a feasibility study.

Authors:  Rajat Agarwala; Alexander Leube; Siegfried Wahl
Journal:  Biomed Opt Express       Date:  2020-10-07       Impact factor: 3.732

5.  Comparison of photorefraction, autorefractometry and retinoscopy in children.

Authors:  Goktug Demirci; Banu Arslan; Mustafa Özsütçü; Mustafa Eliaçık; Gokhan Gulkilik
Journal:  Int Ophthalmol       Date:  2013-10-10       Impact factor: 2.031

6.  The relationship between anisometropia, patient age, and the development of amblyopia.

Authors:  Sean P Donahue
Journal:  Trans Am Ophthalmol Soc       Date:  2005

7.  Photoleukocoria with smartphone photographs.

Authors:  Víctor Manuel Asensio-Sánchez; Lucía Díaz-Cabanas; Alba Martín-Prieto
Journal:  Int Med Case Rep J       Date:  2018-05-16
  7 in total