Literature DB >> 10961218

[Volume-artifact reduction technique by spiral CT in the anterior, middle and posterior cranial fossae. Comparison with conventional cranial CT].

U Dorenbeck1, T Finkenzeller, K Hill, S Feuerbach, J Link.   

Abstract

PURPOSE: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode).
METHODS: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated.
RESULTS: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosal bone, at the internal occipital crest, and at the level of the transverse sinus (p < 0.005).
CONCLUSIONS: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae.

Entities:  

Mesh:

Year:  2000        PMID: 10961218     DOI: 10.1055/s-2000-347

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  4 in total

1.  Image quality of multisection CT of the brain: thickly collimated sequential scanning versus thinly collimated spiral scanning with image combining.

Authors:  M van Straten; H W Venema; C B L M Majoie; N J M Freling; C A Grimbergen; G J den Heeten
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

2.  Cranial CT with 64-, 16-, 4- and single-slice CT systems-comparison of image quality and posterior fossa artifacts in routine brain imaging with standard protocols.

Authors:  Birgit Ertl-Wagner; Lara Eftimov; Jeffrey Blume; Roland Bruening; Christoph Becker; Jean Cormack; Hartmut Brueckmann; Maximilian Reiser
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

3.  Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

Authors:  Holger Wenz; Máté E Maros; Mathias Meyer; Alex Förster; Holger Haubenreisser; Stefan Kurth; Stefan O Schoenberg; Thomas Flohr; Christianne Leidecker; Christoph Groden; Johann Scharf; Thomas Henzler
Journal:  PLoS One       Date:  2015-08-19       Impact factor: 3.240

4.  Levels of brain natriuretic peptide as a marker for the diagnosis and prognosis of acute ischemic stroke.

Authors:  Saadet Sayan; Dilcan Kotan
Journal:  Arch Med Sci Atheroscler Dis       Date:  2016-05-09
  4 in total