Literature DB >> 10953905

Ratings of perceived exertion in braille: validity and reliability in production mode.

J P Buckley1, R G Eston, J Sim.   

Abstract

OBJECTIVES: (a) To assess the validity and reliability of producing and reproducing a given exercise intensity during cycle ergometry using a braille version of Borg's standard 6-20 rating of perceived exertion (RPE) scale, and (b) to determine whether the exercise responses of blind participants, at a given produced RPE, were similar to those reported in recognised guidelines for sighted subjects.
METHODS: Ten healthy registered blind volunteer participants (four women, six men; mean (SD) age 23.2 (9.0) years) performed an initial graded exercise cycle test to determine maximal heart rate (HRMAx) and maximal oxygen uptake (VO2MAX). Three trials of three exercise bouts at RPEs 9, 11, and 13 were then performed in random order on three separate days of the same week, with expired air and heart rate measured continuously. Each exercise bout was followed by 10 minutes of rest. The validity of the scale as a means of producing different exercise intensities was assessed using a two factor (RPE x trial) repeated measures analysis of variance. Intertrial reliability was assessed using intraclass correlation coefficients (ICC) and the bias +/-95% limits of agreement (95%LoA) procedure.
RESULTS: Participants reported no difficulty in using the braille RPE scale. When asked to produce exercise intensities equating to RPE 9, 11, and 13, they elicited mean %VO2MAX values of 47%, 53%, and 63% respectively. Analysis of variance showed no significant differences in either %HRMAx or %VO2MAX between trials at each of the three RPEs, but there was a significant difference (p<0.001) in both %HRMAx and %VO2MAX between the three RPE levels. All pairwise comparisons of the three different RPEs were significantly different (p<0.016). The ICC between the second and third trial for %HRMAx was significant (p <0.05) for all three RPEs. Similarly for %VO2MAX, the ICC was significant for RPE 9 and 11 but not 13. The 95%LoA decreased for both %HRMAx and %VO2MAX with each successive trial.
CONCLUSIONS: Blind participants were successful in using a braille RPE scale to differentiate exercise intensity on a cycle ergometer. In every trial at RPE 13, all participants achieved %HRMAX and %VO2MAX levels, which fell within the recommendedrange for developing cardiorespiratory fitness. Using %HRMAx as a judge of intertrial reliability, the participants were able to repeat similar exercise intensities after two trials at each of the three RPEs (9, 11,13). The same was true for RPE 9 and 11, when %VO2MAX was used as a judge, but further trials were required to achieve similar reliability at RPE 13. A braille RPE scale can be used by healthy blind people during cycle ergometry, with similar effect to the visual analogue scale recommended for use in healthy sighted people.

Entities:  

Mesh:

Year:  2000        PMID: 10953905      PMCID: PMC1724220          DOI: 10.1136/bjsm.34.4.297

Source DB:  PubMed          Journal:  Br J Sports Med        ISSN: 0306-3674            Impact factor:   13.800


  23 in total

1.  Reliability of ratings of perceived exertion during progressive treadmill exercise.

Authors:  K L Lamb; R G Eston; D Corns
Journal:  Br J Sports Med       Date:  1999-10       Impact factor: 13.800

2.  The validity of regulating exercise intensity by ratings of perceived exertion.

Authors:  C C Dunbar; R J Robertson; R Baun; M F Blandin; K Metz; R Burdett; F L Goss
Journal:  Med Sci Sports Exerc       Date:  1992-01       Impact factor: 5.411

3.  The validity and reliability of a rating scale of perceived exertion.

Authors:  J S Skinner; R Hutsler; V Bergsteinová; E R Buskirk
Journal:  Med Sci Sports       Date:  1973

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 5.  Perceived exertion. Antecedents and applications.

Authors:  B Watt; R Grove
Journal:  Sports Med       Date:  1993-04       Impact factor: 11.136

Review 6.  Prescribing exercise intensity for healthy adults using perceived exertion.

Authors:  R K Dishman
Journal:  Med Sci Sports Exerc       Date:  1994-09       Impact factor: 5.411

7.  Accuracy and reproducibility of an exercise prescription based on Ratings of Perceived Exertion for treadmill and cycle ergometer exercise.

Authors:  C C Dunbar; C Goris; D W Michielli; M I Kalinski
Journal:  Percept Mot Skills       Date:  1994-06

8.  Physical fitness of blind and sighted children.

Authors:  W G Hopkins; H Gaeta; A C Thomas; P M Hill
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

9.  Use of perceived effort ratings to control exercise intensity in young healthy adults.

Authors:  R G Eston; B L Davies; J G Williams
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

10.  Reliability of ratings of perceived effort regulation of exercise intensity.

Authors:  R G Eston; J G Williams
Journal:  Br J Sports Med       Date:  1988-12       Impact factor: 13.800

View more
  13 in total

1.  Reliability and validity of measures taken during the Chester step test to predict aerobic power and to prescribe aerobic exercise.

Authors:  J P Buckley; J Sim; R G Eston; R Hession; R Fox
Journal:  Br J Sports Med       Date:  2004-04       Impact factor: 13.800

2.  A perceptually regulated, graded exercise test predicts peak oxygen uptake during treadmill exercise in active and sedentary participants.

Authors:  Roger Eston; Harrison Evans; James Faulkner; Danielle Lambrick; Harran Al-Rahamneh; Gaynor Parfitt
Journal:  Eur J Appl Physiol       Date:  2012-01-26       Impact factor: 3.078

3.  Perceived exertion as a tool to self-regulate exercise in individuals with tetraplegia.

Authors:  Thomas A W Paulson; Nicolette C Bishop; Christof A Leicht; Victoria L Goosey-Tolfrey
Journal:  Eur J Appl Physiol       Date:  2012-05-29       Impact factor: 3.078

4.  Prediction of peak oxygen uptake from age and power output at RPE 15 in obese women.

Authors:  Jérémy B J Coquart; Roger G Eston; Jean-Marie Grosbois; Christine Lemaire; Alain-Eric Dubart; David-Pol Luttenbacher; Murielle Garcin
Journal:  Eur J Appl Physiol       Date:  2010-06-08       Impact factor: 3.078

5.  The validity of predicting maximal oxygen uptake from a perceptually-regulated graded exercise test.

Authors:  Roger G Eston; Kevin L Lamb; Gaynor Parfitt; Nicholas King
Journal:  Eur J Appl Physiol       Date:  2005-04-07       Impact factor: 3.078

Review 6.  The role of information processing between the brain and peripheral physiological systems in pacing and perception of effort.

Authors:  Alan St Clair Gibson; Estelle V Lambert; Laurie H G Rauch; Ross Tucker; Denise A Baden; Carl Foster; Timothy D Noakes
Journal:  Sports Med       Date:  2006       Impact factor: 11.136

7.  The validity and reliability of predicting maximal oxygen uptake from a treadmill-based sub-maximal perceptually regulated exercise test.

Authors:  Michael Morris; Kevin L Lamb; John Hayton; David Cotterrell; John Buckley
Journal:  Eur J Appl Physiol       Date:  2010-03-30       Impact factor: 3.078

8.  Construct and concurrent validation of a new resistance intensity scale for exercise with thera-band® elastic bands.

Authors:  Juan C Colado; Xavier Garcia-Masso; N Travis Triplett; Joaquin Calatayud; Jorge Flandez; David Behm; Michael E Rogers
Journal:  J Sports Sci Med       Date:  2014-12-01       Impact factor: 2.988

9.  The validity of predicting maximal oxygen uptake from perceptually regulated graded exercise tests of different durations.

Authors:  Roger G Eston; James A Faulkner; Elizabeth A Mason; Gaynor Parfitt
Journal:  Eur J Appl Physiol       Date:  2006-06-09       Impact factor: 3.078

Review 10.  Prediction of maximal or peak oxygen uptake from ratings of perceived exertion.

Authors:  Jérémy B Coquart; Murielle Garcin; Gaynor Parfitt; Claire Tourny-Chollet; Roger G Eston
Journal:  Sports Med       Date:  2014-05       Impact factor: 11.136

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.