Literature DB >> 10951369

Influence of isostatic compression on the stability of vancomycin loaded with a calcium phosphate-implantable drug delivery device.

H Gautier1, J Caillon, A M Le Ray, G Daculsi, C Merle.   

Abstract

It is essential to prevent microbial infections after osteoarticular trauma or prosthesis implantation. As an alternative to antibiotic parenteral administration, antibiotic-loaded biomaterials allow high concentrations to be obtained in situ without systemic toxicity. Although the formulation of biphasic calcium-phosphate (BCP)-vancomycin granules by isostatic compression has recently been used to produce drug-delivery devices, the stability of vancomycin needs to be proven. In this study, vancomycin was associated with BCP powders by isostatic compression at 100, 140, or 200 MPa and then extracted or released by a rotating paddle system for 24 h. Vancomycin assays were performed by spectrophotometric and microbiological methods. The results show that all vancomycin associated with the material was recovered after extraction without degradation. Thus, vancomycin was not denaturated after application of 100, 140, or 200 MPa of isostatic compression. The results for vancomycin released from granules compressed at the three pressures were not significantly different (p =.01) whether assays were performed microbiologically or spectrophotometrically, indicating a good correlation between the two methods. This process involving high pressure appears to be a good means of developing drug delivery devices loaded with therapeutic agents without denaturating the components. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10951369     DOI: 10.1002/1097-4636(200011)52:2<308::aid-jbm9>3.0.co;2-6

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  3 in total

1.  In vitro and in vivo bactericidal activities of vancomycin dispersed in porous biodegradable poly(epsilon-caprolactone) microparticles.

Authors:  Anne-Marie Le Ray; Hélène Gautier; Marie-Katel Laty; Guy Daculsi; Christian Merle; Cédric Jacqueline; Antoine Hamel; Jocelyne Caillon
Journal:  Antimicrob Agents Chemother       Date:  2005-07       Impact factor: 5.191

2.  In vitro characterisation of calcium phosphate biomaterials loaded with lidocaine hydrochloride and morphine hydrochloride.

Authors:  H Gautier; V Chamblain; P Weiss; C Merle; J M Bouler
Journal:  J Mater Sci Mater Med       Date:  2010-11-03       Impact factor: 3.896

3.  Effect of metal-ion-to-fuel ratio on the phase formation of bioceramic phosphates synthesized by self-propagating combustion.

Authors:  Swamiappan Sasikumar; Rajagopalan Vijayaraghavan
Journal:  Sci Technol Adv Mater       Date:  2008-09-01       Impact factor: 8.090

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.