Literature DB >> 10946029

Heparin-coated Wiktor stents in human coronary arteries (MENTOR trial). MENTOR Trial Investigators.

M C Vrolix1, V M Legrand, J H Reiber, G Grollier, M J Schalij, P Brunel, L Martinez-Elbal, M Gomez-Recio, F W Bär, M E Bertrand, A Colombo, J Brachman.   

Abstract

The purpose of this study was to determine the feasibility, safety, and efficacy of elective stenting with heparin-coated Wiktor stents in patients with coronary artery disease. In experimental studies, heparin coating has been shown to prevent subacute thrombosis and restenosis. Recently, a new method of heparin coating was developed, resulting in a more stable and predictable heparin layer on stent devices. This trial constitutes the first in-human use of this coating procedure, applied on the well-known Wiktor stent device. Heparin-coated Wiktor stent implantation was performed in 132 consecutive patients (132 lesions) in a multicenter international trial from September 1996 to February 1997. Forty-three percent of patients had unstable angina, 33% had previous myocardial infarction, and 10% had diabetes mellitus. Patients were followed for 12 months for occurrence of major adverse cardiovascular events, and 96% of the eligible patients underwent quantitative angiographic control at 6 months. Stent deployment was successful in 95.5% of lesions. Minimal lumen diameter increased by 1.67 +/- 0.48 mm (from 1.02 +/- 0.38 mm before to 2.69 +/- 0.37 mm after the stent implantation). Mean percent diameter stenosis decreased from 67.4 +/- 11.3% before to 18.9 +/- 7.7% after the intervention. A successful intervention (<50% diameter stenosis and no major adverse cardiac events within 30 days) occurred in 97% of the patients. The subacute thrombosis rate was 0.8%, which compares favorably with historical controls of this stent, and a low incidence of postprocedural increase in creatine kinase-MB was noted. At 6 months, event-free survival was 85% and angiographic restenosis rate was 22% with late loss of 0.78 +/- 0.69 mm and a loss index of 0.48 +/- 0.44. Heparin-coated Wiktor stents appeared to be an efficacious device to treat Benestent-like lesions, yielding angiographic and clinical results comparable to a heparin-coated Palmaz-Schatz stent. Despite its use in more complex lesions, the incidence of subacute thrombosis appeared to be lower than historical controls with a similar noncoated stent.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10946029     DOI: 10.1016/s0002-9149(00)00951-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  10 in total

1.  Development of a polymer stent with shape memory effect as a drug delivery system.

Authors:  H M Wache; D J Tartakowska; A Hentrich; M H Wagner
Journal:  J Mater Sci Mater Med       Date:  2003-02       Impact factor: 3.896

Review 2.  Coronary stents: in these days of climate change should all stents wear coats?

Authors:  R Lowe; I B A Menown; G Nogareda; I M Penn
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

3.  Thromboresistant and endothelialization effects of dopamine-mediated heparin coating on a stent material surface.

Authors:  In-Ho Bae; In-Kyu Park; Dae Sung Park; Haeshin Lee; Myung Ho Jeong
Journal:  J Mater Sci Mater Med       Date:  2012-03-03       Impact factor: 3.896

Review 4.  Anti-fouling strategies for central venous catheters.

Authors:  Alex Wallace; Hassan Albadawi; Nikasha Patel; Ali Khademhosseini; Yu Shrike Zhang; Sailendra Naidu; Grace Knuttinen; Rahmi Oklu
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

5.  Heparin promotes platelet responsiveness by potentiating αIIbβ3-mediated outside-in signaling.

Authors:  Cunji Gao; Brian Boylan; Juan Fang; David A Wilcox; Debra K Newman; Peter J Newman
Journal:  Blood       Date:  2011-03-02       Impact factor: 22.113

6.  Hemodynamic Performance and Thrombogenic Properties of a Superhydrophobic Bileaflet Mechanical Heart Valve.

Authors:  David L Bark; Hamed Vahabi; Hieu Bui; Sanli Movafaghi; Brandon Moore; Arun K Kota; Ketul Popat; Lakshmi P Dasi
Journal:  Ann Biomed Eng       Date:  2016-04-20       Impact factor: 3.934

7.  Preparation and experimental research into retrievable rapamycin- and heparin-coated vena cava filters: a pilot study.

Authors:  Hui Zhao; Fuxian Zhang; Gangzhu Liang; Lin Ye; Huan Zhang; Luyuan Niu; Long Cheng; Mingyi Zhang
Journal:  J Thromb Thrombolysis       Date:  2016-04       Impact factor: 2.300

Review 8.  Recent advances in drug eluting stents.

Authors:  Amey S Puranik; Eileen R Dawson; Nicholas A Peppas
Journal:  Int J Pharm       Date:  2012-10-29       Impact factor: 5.875

Review 9.  A bumpy and winding but right path to domestic drug-eluting coronary stents.

Authors:  Jae Yeong Cho; Youngkeun Ahn; Myung Ho Jeong
Journal:  Korean Circ J       Date:  2013-10       Impact factor: 3.243

Review 10.  Thrombogenic and Inflammatory Reactions to Biomaterials in Medical Devices.

Authors:  Carlos A Labarrere; Ali E Dabiri; Ghassan S Kassab
Journal:  Front Bioeng Biotechnol       Date:  2020-03-12
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.