UNLABELLED: This study was designed to elucidate the usefulness of crosstalk correction for dual-isotope simultaneous acquisition (DISA) with 99mTc-tetrofosmin and FDG in estimating myocardial perfusion and viability. METHODS: Eighteen patients with coronary artery disease were studied. First, SPECT was performed with a low-energy high-resolution collimator after a single injection of 99mTc-tetrofosmin (single 99mTc-tetrofosmin). Second, PET and DISA with an ultra-high-energy collimator were performed after glucose loading and an injection of FDG. DISA was designed to operate with simultaneous 3-channel acquisition, and weighted scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak was performed by modification of an existing dual-window technique. The FDG SPECT images were compared with the images obtained by PET. Both crosstalk-corrected and uncorrected 99mTc-tetrofosmin images were generated and compared with the single 99mTc-tetrofosmin images. RESULTS: Regional percentage uptake of FDG agreed well between DISA and PET. However, regional percentage uptake of 99mTc-tetrofosmin was generally higher on the uncorrected 99mTc-tetrofosmin images than on the single 99mTc-tetrofosmin images, especially in areas of low flow (percentage count of 99mTc-tetrofosmin > or = 50%). The crosstalk correction contributed to improving the agreement between regional percentage uptakes and significantly improved the detectability of myocardial perfusion-metabolism mismatching. CONCLUSION: With 3-channel acquisition and weighted-scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak, DISA with 99mTc-tetrofosmin and FDG is feasible for assessing regional myocardial perfusion and viability.
UNLABELLED: This study was designed to elucidate the usefulness of crosstalk correction for dual-isotope simultaneous acquisition (DISA) with 99mTc-tetrofosmin and FDG in estimating myocardial perfusion and viability. METHODS: Eighteen patients with coronary artery disease were studied. First, SPECT was performed with a low-energy high-resolution collimator after a single injection of 99mTc-tetrofosmin (single 99mTc-tetrofosmin). Second, PET and DISA with an ultra-high-energy collimator were performed after glucose loading and an injection of FDG. DISA was designed to operate with simultaneous 3-channel acquisition, and weighted scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak was performed by modification of an existing dual-window technique. The FDG SPECT images were compared with the images obtained by PET. Both crosstalk-corrected and uncorrected 99mTc-tetrofosmin images were generated and compared with the single 99mTc-tetrofosmin images. RESULTS: Regional percentage uptake of FDG agreed well between DISA and PET. However, regional percentage uptake of 99mTc-tetrofosmin was generally higher on the uncorrected 99mTc-tetrofosmin images than on the single 99mTc-tetrofosmin images, especially in areas of low flow (percentage count of 99mTc-tetrofosmin > or = 50%). The crosstalk correction contributed to improving the agreement between regional percentage uptakes and significantly improved the detectability of myocardial perfusion-metabolism mismatching. CONCLUSION: With 3-channel acquisition and weighted-scatter correction of crosstalk from the 18F photopeak to the 99mTc photopeak, DISA with 99mTc-tetrofosmin and FDG is feasible for assessing regional myocardial perfusion and viability.
Authors: Riemer H J A Slart; Jeroen J Bax; Dirk J van Veldhuisen; Ernst E van der Wall; Rudi A J O Dierckx; Pieter L Jager Journal: Int J Cardiovasc Imaging Date: 2005-12-13 Impact factor: 2.357
Authors: Riemer H J A Slart; Jeroen J Bax; Jaep de Boer; Antoon T M Willemsen; Piet H Mook; Matthijs Oudkerk; Ernst E van der Wall; Dirk J van Veldhuisen; Pieter L Jager Journal: Eur J Nucl Med Mol Imaging Date: 2005-04-12 Impact factor: 9.236
Authors: Riemer H J A Slart; Jeroen J Bax; Dirk J van Veldhuisen; Ernst E van der Wall; Roy Irwan; Wim J Sluiter; Rudi A Dierckx; Jaep de Boer; Pieter L Jager Journal: Eur J Nucl Med Mol Imaging Date: 2006-03-08 Impact factor: 9.236