Literature DB >> 10945383

The effect of lung injury and excessive lung fluid, on impedance cardiac output measurements, in the critically ill.

L A Critchley1, R M Calcroft, P Y Tan, J Kew, J A Critchley.   

Abstract

OBJECTIVES: To investigate the relationship between the attenuation of impedance cardiac output (IC(co)) measurements and lung fluid content in critically ill patients.
DESIGN: Observational study.
SETTING: Intensive Care Unit of a major teaching hospital in Hong Kong. PATIENTS: Twenty-four critically ill patients who required a pulmonary artery catheter.
MEASUREMENTS AND MAIN RESULTS: Triplicate thermodilution cardiac output (TD(co)) and BoMed NCCOM3 (IC(co)) measurements were made simultaneously on a single occasion in each patient. Lung fluid accumulation was assessed by: (a) thoracic impedance (Zo), (b) radiological assessment of chest X-rays using an alveolar consolidation score (0-4) and (c) scoring the degree of hypoxia and use of positive end-expiratory pressure (PEEP). Offsets (TD(co)-IC(co))/TD(co), expressed as percentage, were compared with these indices of excess lung fluid. Patients were divided into those with sepsis (n = 13), fluid balance problems (n = 5) and cardiothoracic problems (n = 6). Mean cardiac output values were: 6.7 l/min TD(co) (range 3.6-12.9) and 5.2 l/min IC(co) (range 2.7-9.0). Overall the TD(co) and IC(co) values showed great variance, with a bias and limits of agreement of 1.49 +/- 4.16 l/min, or +/- 69%. In septic patients, increasing offset was correlated with decreases in Zo (r = 0.73, P = 0.005) and increases in alveolar consolidation score (r = 0.72, P = 0.005).
CONCLUSIONS: The BoMed under-estimates cardiac output in critically ill patients. In septic patients the degree of attenuation of IC(co) can be related to the extent of lung injury and fluid accumulation within the thorax.

Entities:  

Mesh:

Year:  2000        PMID: 10945383     DOI: 10.1007/s001340051232

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  5 in total

1.  Stroke volume equation for impedance cardiography.

Authors:  D P Bernstein; H J M Lemmens
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

2.  Short-term postural reflexes in diabetic patients with autonomic dysfunction.

Authors:  Y Zhang; L A Critchley; Y H Tam; B Tomlinson
Journal:  Diabetologia       Date:  2003-12-03       Impact factor: 10.122

3.  Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements.

Authors:  Matthias Heringlake; Ulrich Handke; Thorsten Hanke; Frank Eberhardt; Jan Schumacher; Hartmut Gehring; Hermann Heinze
Journal:  Intensive Care Med       Date:  2007-08-10       Impact factor: 17.440

4.  Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.

Authors:  Donald P Bernstein; Isaac C Henry; Harry J Lemmens; Janell L Chaltas; Anthony N DeMaria; James B Moon; Andrew M Kahn
Journal:  J Clin Monit Comput       Date:  2015-02-15       Impact factor: 2.502

5.  Improved pressure contour analysis for estimating cardiac stroke volume using pulse wave velocity measurement.

Authors:  Shun Kamoi; Christopher Pretty; Joel Balmer; Shaun Davidson; Antoine Pironet; Thomas Desaive; Geoffrey M Shaw; J Geoffrey Chase
Journal:  Biomed Eng Online       Date:  2017-04-24       Impact factor: 2.819