Literature DB >> 10945360

Focal hepatic ablation using interstitial photon radiation energy.

L G Koniaris1, D Y Chan, C Magee, S B Solomon, J H Anderson, D O Smith, T De Weese, L R Kavoussi, M A Choti.   

Abstract

BACKGROUND: Intratumoral ablative therapy is being used increasingly for the treatment of primary and secondary hepatic malignancies. The interstitial point-source photon radiosurgery system (PRS) is a novel ablative technique that uses radiation therapy similar in dosimetry to interstitial brachytherapy. STUDY
DESIGN: To determine the feasibility, toxicity, and local tissue destructive capabilities of the PRS in the liver, preliminary studies in a nontumor-bearing canine model were examined. A 6-month survival study was conducted. Each animal received three radiation treatments, in the right, central, and left hepatic regions. Three low-dose treatments were delivered to each of six animals (group A), generating a 2.0-cm-diameter radiated sphere with a dose of 20 Gy at the lesion edge. Three high-dose treatments were delivered to each of six animals (group B), generating a 3.0-cm-diameter radiated sphere with 20 Gy at the lesion edge.
RESULTS: The treatment reproducibly generated sharply demarcated hepatic ablative lesions proportional to the administered dose. Mean lesion diameter at 1 month was 1.6+/-0.2 cm in group A and 3.4+/-1.0 cm in group B. Lesion size was independent of intrahepatic location, including near vascular structures. PRS therapy, when applied to portal structures, resulted in hilar damage. Hilar damage appeared to be associated with arteriolar thrombosis and bile duct injury. Treatment of regions adjacent to large hepatic veins and the IVC was not associated with vessel thrombosis or stricture.
CONCLUSIONS: PRS ablation is a generally well-tolerated method that results in consistent, well-demarcated, symmetric lesions of complete necrosis with minimal adjacent parenchymal injury. Application of such an approach for the treatment of liver tumors is promising.

Entities:  

Mesh:

Year:  2000        PMID: 10945360     DOI: 10.1016/s1072-7515(00)00295-7

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  2 in total

1.  Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation.

Authors:  Emad M Boctor; Michael A Choti; Everette C Burdette; Robert J Webster Iii
Journal:  Int J Med Robot       Date:  2008-06       Impact factor: 2.547

Review 2.  Locoregional therapies for hepatocellular carcinoma: a critical review from the surgeon's perspective.

Authors:  Ronnie Tung-Ping Poon; Sheung-Tat Fan; Flora Hau-Fung Tsang; John Wong
Journal:  Ann Surg       Date:  2002-04       Impact factor: 12.969

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.