Literature DB >> 10943926

Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams.

M A Cliftt1, R A Sutton, D V Webb.   

Abstract

Plastic organic scintillators are often considered 'water equivalent' in megavoltage photon beams as they have similar atomic composition and density to water. Two plastic scintillators are evaluated for their 'water equivalence', using the Burlin cavity theory, in the photon energy range of 200 keV to 20 MeV. The Burlin theory predicts that the two investigated scintillator materials are likely to be 'water equivalent' in the energy range investigated. The prediction of the Burlin theory for one of these scintillators has been confirmed by absorbed dose measurements in bremsstrahlung beams between 13 and 19 MeV.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10943926     DOI: 10.1088/0031-9155/45/7/313

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.

Authors:  Mathieu Guillot; Luc Gingras; Louis Archambault; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

3.  Technical note: determining regions of interest for CCD camera-based fiber optic luminescence dosimetry by examining signal-to-noise ratio.

Authors:  David M Klein; Francois Therriault-Proulx; Louis Archambault; Tina M Briere; Luc Beaulieu; A Sam Beddar
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

4.  In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors.

Authors:  David Klein; Tina Marie Briere; Rajat Kudchadker; Louis Archambault; Luc Beaulieu; Andrew Lee; Sam Beddar
Journal:  Radiat Meas       Date:  2012-08-24       Impact factor: 1.898

5.  A portable organic plastic scintillator dosimetry system for low energy X-rays: A feasibility study using an intraoperative X-ray unit as the radiation source.

Authors:  Kerry Williams; Neil Robinson; Jamie Trapp; Trevor Ackerly; Ram Das; Penny Kemp; Moshi Geso
Journal:  J Med Phys       Date:  2007-04

6.  Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry.

Authors:  Wook Jae Yoo; Jinsoo Moon; Kyoung Won Jang; Ki-Tek Han; Sang Hun Shin; Dayeong Jeon; Jang-Yeon Park; Byung Gi Park; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2012-05-14       Impact factor: 3.576

7.  Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

Authors:  Wook Jae Yoo; Sang Hun Shin; Dayeong Jeon; Seunghan Hong; Hyeok In Sim; Seon Geun Kim; Kyoung Won Jang; Seunghyun Cho; Won Sik Youn; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2014-04-01       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.