Comparison of apnea identified by respiratory inductance plethysmography with that detected by end-tidal CO(2) or thermistor. The CHIME Study Group.

D E Weese-Mayer1, M J Corwin, M R Peucker, J M Di Fiore, D R Hufford, L R Tinsley, M R Neuman, R J Martin, L J Brooks, S L Davidson Ward, G Lister, M Willinger.   

Abstract

As part of the Collaborative Home Infant Monitoring Evaluation (CHIME) we compared apnea identified by a customized home monitor using respiratory inductance plethysmography (RIP) with simultaneously recorded polysomnography-acquired nasal end-tidal CO(2) (PET(CO(2))) and nasal/oral thermistor in 422 infants during overnight laboratory recordings to determine concordance between techniques, sources of disagreement, and capacity of RIP to detect obstructed breaths within an apnea. Among 233 episodes of apnea identified by at least one method as >/= 16 s, 120 were observed by the CHIME monitor, 219 by PET(CO(2)), and 163 by thermistor. The positive predictive value of the CHIME-identified apnea was 89.2% (95% CI 83, 95) and 73% (95% CI 65, 81) for PET(CO(2)) and thermistor, respectively. However, the sensitivity of the CHIME monitor in identifying events detected by the other methods was only approximately 50%. Among 87 apnea events identified by all three techniques, no two methods showed high agreement in measurement of apnea duration: RIP and PET(CO(2)) (ICC = 0.54), RIP and thermistor (ICC = 0.13), PET(CO(2)) and nasal thermistor (ICC = 0.41). Among the 179 breaths identified by RIP as obstructed, 79.9% were judged to be obstructed on the PET(CO(2)) and 80.4% were judged to be obstructed on the thermistor channel. Among 238 breaths identified on PET(CO(2)) as obstructed, 54.2% were determined to be obstructed by RIP. Among 204 breaths identified on thermistor as obstructed, 55. 4% were determined to be obstructed by RIP. Reasons for discrepancies in apnea detection among channels included body movement, partial airway obstruction, and obstructed breaths. Despite these limitations the CHIME monitor provides an opportunity to record physiological data previously unavailable in the home.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10934073     DOI: 10.1164/ajrccm.162.2.9904029

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  9 in total

Review 1.  Diagnostic issues in pediatric obstructive sleep apnea.

Authors:  Hiren Muzumdar; Raanan Arens
Journal:  Proc Am Thorac Soc       Date:  2008-02-15

2.  Relationship between sleep position and risk of extreme cardiorespiratory events.

Authors:  George Lister; Denis V Rybin; Theodore Colton; Timothy C Heeren; Carl E Hunt; Eve R Colson; Marian Willinger; Michael J Corwin
Journal:  J Pediatr       Date:  2012-02-23       Impact factor: 4.406

3.  Real-time detection, classification, and quantification of apneic episodes using miniature surface motion sensors in rats.

Authors:  Dan Waisman; Lior Lev-Tov; Carmit Levy; Anna Faingersh; Ifat Colman Klotzman; Haim Bibi; Avi Rotschild; Amir Landesberg
Journal:  Pediatr Res       Date:  2015-03-31       Impact factor: 3.756

4.  Racial and Ethnic Trends in Sudden Unexpected Infant Deaths: United States, 1995-2013.

Authors:  Sharyn E Parks; Alexa B Erck Lambert; Carrie K Shapiro-Mendoza
Journal:  Pediatrics       Date:  2017-05-15       Impact factor: 7.124

5.  Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine.

Authors:  Richard B Berry; Rohit Budhiraja; Daniel J Gottlieb; David Gozal; Conrad Iber; Vishesh K Kapur; Carole L Marcus; Reena Mehra; Sairam Parthasarathy; Stuart F Quan; Susan Redline; Kingman P Strohl; Sally L Davidson Ward; Michelle M Tangredi
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

6.  Characterization of cardiorespiratory events following gastroesophageal reflux in preterm infants.

Authors:  J Di Fiore; M Arko; B Herynk; R Martin; A M Hibbs
Journal:  J Perinatol       Date:  2010-03-11       Impact factor: 2.521

7.  A flow-through capnometer for obstructive sleep apnea.

Authors:  Shinji Yamamori; Yuji Takasaki; Makoto Ozaki; Hiroshi Iseki
Journal:  J Clin Monit Comput       Date:  2008-05-28       Impact factor: 2.502

8.  Quantitative Analysis of Thoracoabdominal Asynchrony in Pediatric Polysomnography.

Authors:  Jason Z Bronstein; Li Xie; Thomas H Shaffer; Aaron Chidekel; Robert Heinle
Journal:  J Clin Sleep Med       Date:  2018-07-15       Impact factor: 4.062

Review 9.  Continuous vital sign analysis for predicting and preventing neonatal diseases in the twenty-first century: big data to the forefront.

Authors:  Navin Kumar; Gangaram Akangire; Brynne Sullivan; Karen Fairchild; Venkatesh Sampath
Journal:  Pediatr Res       Date:  2019-08-04       Impact factor: 3.756

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.