A multicenter validation of an active contour-based left ventricular analysis technique.

M J Graves1, E Berry, A A Eng, M Westhead, R T Black, D J Beacock, S Kelly, P Niemi.   

Abstract

Quantitative analysis of functional cardiac magnetic resonance (MR) images has been limited by the lack of well-validated, semiautomatic, methods for rapid analysis. We describe the evaluation of a DICOM-compatible PC-based parallel-processing tool, for cardiac magnetic resonance analysis (CAMRA), which supports semiautomatic image mensuration using an active contour model-based algorithm. The CAMRA software was used to analyze data from 12 patients in a multicenter acquisition and analysis trial to compare semiautomatic contour detection with manual planimetry of the left ventricular endocardium from short-axis, breath-held, cine gradient-echo images. There was excellent agreement between the manual and semiautomatic measurements of global left ventricular function, with no significant (P = 0.32) difference in the determination of ejection fraction (-0.9 +/- 3.1% [mean difference +/- 1 standard deviation]). There was no significant interobserver difference in the semiautomatically measured ejection fraction. Additionally, a single observer completed the analysis on data from 30 patients and found no significant (P = 0.05) difference in the determination of ejection fraction (-1.3 +/- 3.5% [mean difference +/- 1 standard deviation]). The CAMRA software demonstrates the capability for the reproducible evaluation of global left ventricular function in cardiac patients, with adequate interobserver reproducibility for use in multicenter trials.

Entities:  

Mesh:

Year:  2000        PMID: 10931585     DOI: 10.1002/1522-2586(200008)12:2<232::aid-jmri4>3.0.co;2-a

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Comparative evaluation of active contour model extensions for automated cardiac MR image segmentation by regional error assessment.

Authors:  Duy Nguyen; Karen Masterson; Jean-Paul Vallée
Journal:  MAGMA       Date:  2007-03-06       Impact factor: 2.310

2.  Improving the reproducibility of MR-derived left ventricular volume and function measurements with a semi-automatic threshold-based segmentation algorithm.

Authors:  Karolien Jaspers; Hendrik G Freling; Kees van Wijk; Elisabeth I Romijn; Marcel J W Greuter; Tineke P Willems
Journal:  Int J Cardiovasc Imaging       Date:  2012-09-29       Impact factor: 2.357

3.  Accurate computer-aided quantification of left ventricular parameters: experience in 1555 cardiac magnetic resonance studies from the Framingham Heart Study.

Authors:  Gilion L T F Hautvast; Carol J Salton; Michael L Chuang; Marcel Breeuwer; Christopher J O'Donnell; Warren J Manning
Journal:  Magn Reson Med       Date:  2011-10-21       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.