Literature DB >> 10925950

An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve.

J T Ellis1, B R Travis, A P Yoganathan.   

Abstract

The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser Doppler velocimetry measurements were conducted within the hinge and near-field forward flow regions of the Regent valve. These pulsatile flow velocity measurements were animated in time to visualize the flow fields throughout the cardiac cycle. During forward flow, a recirculation region developed in the inflow pocket of the Regent hinge but was subsequently abolished by strong backflow during valve closure. Leakage velocities in the hinge region reached 0.72 m/s and Reynolds shear stresses reached 2,600 dyn/cm2. Velocities in the near-field region were highest in the lateral orifice jet, reaching 2.1 m/s. Small regions of separated flow were observed adjacent to the hinge region. Leaflet motion through the Regent hinge creates a washout pattern which restricts the persistence of stagnation zones in its hinge. Based upon the results of these studies, the hematological performance of the Regent series should be at least equivalent to the performance of the Standard series.

Entities:  

Mesh:

Year:  2000        PMID: 10925950     DOI: 10.1114/1.297

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  10 in total

1.  Constricted microfluidic devices to study the effects of transient high shear exposure on platelets.

Authors:  Nesreen Z Alsmadi; Sarah J Shapiro; Christopher S Lewis; Vinit M Sheth; Trevor A Snyder; David W Schmidtke
Journal:  Biomicrofluidics       Date:  2017-11-28       Impact factor: 2.800

2.  Numerical investigation of the performance of three hinge designs of bileaflet mechanical heart valves.

Authors:  Hélène A Simon; Liang Ge; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2010-06-23       Impact factor: 3.934

3.  Characteristic localization patterns of thrombus on various brands of bileaflet mitral mechanical heart valves as assessed by three-dimensional transesophageal echocardiography and their relationship with thromboembolism.

Authors:  Munevver Sari; Zubeyde Bayram; Mehmet Ayturk; Emrah Bayam; Semih Kalkan; Ahmet Guner; Macit Kalcik; Mustafa Ozan Gursoy; Sabahattin Gunduz; Mehmet Ozkan
Journal:  Int J Cardiovasc Imaging       Date:  2021-04-09       Impact factor: 2.357

Review 4.  Simulation of Mechanical Heart Valve Dysfunction and the Non-Newtonian Blood Model Approach.

Authors:  Aolin Chen; Adi Azriff Bin Basri; Norzian Bin Ismail; Masaaki Tamagawa; Di Zhu; Kamarul Arifin Ahmad
Journal:  Appl Bionics Biomech       Date:  2022-04-19       Impact factor: 1.664

5.  Impact of design parameters on bileaflet mechanical heart valve flow dynamics.

Authors:  Vijay Govindarajan; Holavanahalli S Udaykumar; Luke H Herbertson; Steven Deutsch; Keefe B Manning; Krishnan B Chandran
Journal:  J Heart Valve Dis       Date:  2009-09

6.  FLOW DYNAMIC COMPARISON BETWEEN RECESSED HINGE AND OPEN PIVOT BI-LEAFLET HEART VALVE DESIGNS.

Authors:  V Govindarajan; H S Udaykumar; K B Chandran
Journal:  J Mech Med Biol       Date:  2009-06-01       Impact factor: 0.897

Review 7.  Fluid mechanics of artificial heart valves.

Authors:  Lakshmi P Dasi; Helene A Simon; Philippe Sucosky; Ajit P Yoganathan
Journal:  Clin Exp Pharmacol Physiol       Date:  2009-02       Impact factor: 2.557

8.  Two-dimensional simulation of flow and platelet dynamics in the hinge region of a mechanical heart valve.

Authors:  V Govindarajan; H S Udaykumar; K B Chandran
Journal:  J Biomech Eng       Date:  2009-03       Impact factor: 2.097

9.  Simulation of the three-dimensional hinge flow fields of a bileaflet mechanical heart valve under aortic conditions.

Authors:  Hélène A Simon; Liang Ge; Iman Borazjani; Fotis Sotiropoulos; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2009-12-04       Impact factor: 3.934

10.  Adverse Hemodynamic Conditions Associated with Mechanical Heart Valve Leaflet Immobility.

Authors:  Fardin Khalili; Peshala P T Gamage; Richard H Sandler; Hansen A Mansy
Journal:  Bioengineering (Basel)       Date:  2018-09-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.