Literature DB >> 10916257

Conversion of magnetocardiographic recordings between two different multichannel SQUID devices.

M Burghoff1, J Nenonen, L Trahms, T Katila.   

Abstract

Comparison of biomagnetic measurements performed with different multichannel magnetometers is difficult, because differing sensor types and locations do not allow measurements from the same locations in respect to the body. In this study, two transformation procedures were utilized to compare magnetocardiograms (MCG) recorded with two different multisensor systems. Signals from one sensor array were used to compute parameters of a multipole expansion or minimum-norm estimates at 1-ms steps over the cardiac cycle. The signals of the second sensor array were then simulated from the computed estimates and compared against measured data. Both the multipole- and the minimum-norm-based transformation method yielded good results; the average correlation between simulated and measured signals was 93%. Thus, the methods are useful to compare MCG recordings performed using differing sensor configurations, e.g., for multicenter patient studies. This study provides the first empirical basis for assessing the transformation of MCG data of differing devices by general model-based field reconstructions.

Entities:  

Mesh:

Year:  2000        PMID: 10916257     DOI: 10.1109/10.846680

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

1.  Magnetocardiographic assessment of healed myocardial infarction.

Authors:  Helena Hänninen; Miia Holmström; Paula Vesterinen; Milla Karvonen; Heikki Väänänen; Lasse Oikarinen; Markku Mäkijärvi; Jukka Nenonen; Kirsi Lauerma; Toivo Katila; Lauri Toivonen
Journal:  Ann Noninvasive Electrocardiol       Date:  2006-07       Impact factor: 1.468

2.  Standard template of adult magnetocardiogram.

Authors:  Akihiko Kandori; Kuniomi Ogata; Tsuyoshi Miyashita; Yasushi Watanabe; Kimio Tanaka; Masahiro Murakami; Yuji Oka; Hiroshi Takaki; Syuji Hashimoto; Yuko Yamada; Kazuo Komamura; Wataru Shimizu; Shiro Kamakura; Shigeyuki Watanabe; Iwao Yamaguchi
Journal:  Ann Noninvasive Electrocardiol       Date:  2008-10       Impact factor: 1.468

3.  Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects.

Authors:  Anna Rita Sorbo; Gianmarco Lombardi; Lara La Brocca; Gianluigi Guida; Riccardo Fenici; Donatella Brisinda
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-12-20       Impact factor: 1.468

4.  Temporal analysis of the depolarization wave of healed myocardial infarction in body surface potential mapping.

Authors:  Paula Vesterinen; Helena Hänninen; Milla Karvonen; Kirsi Lauerma; Miia Holmström; Markku Mäkijärvi; Heikki Väänänen; Jukka Nenonen; Toivo Katila; Lauri Toivonen
Journal:  Ann Noninvasive Electrocardiol       Date:  2004-07       Impact factor: 1.468

5.  Head movements of children in MEG: quantification, effects on source estimation, and compensation.

Authors:  Daniel T Wehner; Matti S Hämäläinen; Maria Mody; Seppo P Ahlfors
Journal:  Neuroimage       Date:  2008-02-05       Impact factor: 6.556

6.  SEM, TEM, and IHC Analysis of the Sinus Node and Its Implications for the Cardiac Conduction System.

Authors:  D Mandrioli; F Ceci; T Balbi; C Ghimenton; G Pierini
Journal:  Anat Res Int       Date:  2013-10-27

7.  Transforming and comparing data between standard SQUID and OPM-MEG systems.

Authors:  Urban Marhl; Anna Jodko-Władzińska; Rüdiger Brühl; Tilmann Sander; Vojko Jazbinšek
Journal:  PLoS One       Date:  2022-01-19       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.