Methods for reducing biosensor membrane biofouling.

.   

Abstract

The deleterious effect that biofouling has on sensor stability is a serious impediment to the development of long term implanted biosensors. This paper reviews the surface modification strategies currently employed to minimize membrane biofouling of in vivo sensors. Nine sensor modifications are discussed herein: hydrogels, phospholipid-based biomimicry, flow-based systems, Nafion, surfactants, naturally derived materials, covalent attachments, diamond-like carbons, and topology.

Entities:  

Year:  2000        PMID: 10915944     DOI: 10.1016/s0927-7765(99)00148-4

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  91 in total

1.  Cyclic olefin copolymer based microfluidic devices for biochip applications: Ultraviolet surface grafting using 2-methacryloyloxyethyl phosphorylcholine.

Authors:  Rajeeb K Jena; C Y Yue
Journal:  Biomicrofluidics       Date:  2012-03-15       Impact factor: 2.800

2.  Analyte flux at a biomaterial-tissue interface over time: implications for sensors for type 1 and 2 diabetes mellitus.

Authors:  Neda Rajamand Ekberg; Kerstin Brismar; Jonas Malmstedt; Mari-Anne Hedblad; Ulf Adamson; Urban Ungerstedt; Natalie Wisniewski
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

3.  Comparison of Insulins Glargine and Degludec in Diabetic Rhesus Macaques (Macaca mulatta) with CGM Devices.

Authors:  Samantha C Puglisi; Alexis L Mackiewicz; Amir Ardeshir; Laura M Garzel; Kari L Christe
Journal:  Comp Med       Date:  2021-05-25       Impact factor: 0.982

4.  Glucose sensor membranes for mitigating the foreign body response.

Authors:  Ahyeon Koh; Scott P Nichols; Mark H Schoenfisch
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

5.  Universal surface-initiated polymerization of antifouling zwitterionic brushes using a mussel-mimetic peptide initiator.

Authors:  Jinghao Kuang; Phillip B Messersmith
Journal:  Langmuir       Date:  2012-04-23       Impact factor: 3.882

6.  The effect of nitric oxide surface flux on the foreign body response to subcutaneous implants.

Authors:  Scott P Nichols; Ahyeon Koh; Nga L Brown; Michael B Rose; Bin Sun; Danielle L Slomberg; Daniel A Riccio; Bruce Klitzman; Mark H Schoenfisch
Journal:  Biomaterials       Date:  2012-06-27       Impact factor: 12.479

7.  Toward an injectable continuous osmotic glucose sensor.

Authors:  Erik Johannessen; Olga Krushinitskaya; Andrey Sokolov; Häfliger Philipp; Arno Hoogerwerf; Christian Hinderling; Kari Kautio; Jaakko Lenkkeri; Esko Strömmer; Vasily Kondratyev; Tor Inge Tønnessen; Tom Eirik Mollnes; Henrik Jakobsen; Even Zimmer; Bengt Akselsen
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

Review 8.  Implantable nanosensors: toward continuous physiologic monitoring.

Authors:  Timothy T Ruckh; Heather A Clark
Journal:  Anal Chem       Date:  2013-12-10       Impact factor: 6.986

9.  Microsphere erosion in outer hydrogel membranes creating macroscopic porosity to counter biofouling-induced sensor degradation.

Authors:  S Vaddiraju; Y Wang; L Qiang; D J Burgess; F Papadimitrakopoulos
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

Review 10.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.