Literature DB >> 10910479

Use of the intubating laryngeal mask airway: are muscle relaxants necessary?

J M van Vlymen1, M Coloma, W K Tongier, P F White.   

Abstract

BACKGROUND: The intubating laryngeal mask airway (ILMA) is designed to facilitate blind tracheal intubation. The effect of a muscle relaxant on the ability to perform tracheal intubation through the ILMA device has not been previously evaluated. This randomized, double-blind, placebo-controlled study was designed to evaluate rocuronium, 0.2 or 0.4 mg/kg administered intravenously, on the success rate and incidence of complications associated with ILMA-assisted tracheal intubation.
METHODS: A total of 75 healthy patients were induced with propofol 2 mg/kg and fentanyl 1 microg/kg intravenously. After insertion of the ILMA device, patients were administered either saline, rocuronium 0.2 mg/kg, or rocuronium 0.4 mg/kg in a total volume of 5 ml. At 90 s after administration of the study drug, tracheal intubation was attempted using a disposable polyvinyl tube. If unsuccessful, a reusable silicone tube was tried. In addition to recording the time and number of attempts required to secure the airway, the incidence of complications during placement of the tracheal tube and removal of the ILMA were noted.
RESULTS: Tracheal intubation was successful in 76-96% of the patients. The overall success rates and times required to secure the airway were similar in all three treatment groups. The high-dose rocuronium group experienced less patient movement (8 vs. 28 and 48%) and coughing (12 vs. 20 and 52%) than the low-dose rocuronium and saline groups, respectively. Use of rocuronium was also associated with a dose-related decrease in the requirement for supplemental bolus doses of propofol during intubation and removal of the ILMA device.
CONCLUSIONS: Use of rocuronium did not significantly improve the success rate in performing tracheal intubation through the ILMA. However, it produced dose-related decreases in coughing and movement after tracheal intubation and reduced difficulties associated with removal of the ILMA device.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10910479     DOI: 10.1097/00000542-200008000-00010

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  7 in total

1.  Crisis management during anaesthesia: difficult intubation.

Authors:  A D Paix; J A Williamson; W B Runciman
Journal:  Qual Saf Health Care       Date:  2005-06

2.  Comparison of the size 3 and size 4 ProSeal™ laryngeal mask airway in anesthetized, non-paralyzed women: a randomized controlled trial.

Authors:  Mi-Hyun Kim; Jung-Won Hwang; Eun-Sung Kim; Sung-Hee Han; Young-Tae Jeon; Sun-Mi Lee
Journal:  J Anesth       Date:  2014-09-24       Impact factor: 2.078

3.  Intubating condition, hemodynamic parameters and upper airway morbidity: A comparison of intubating laryngeal mask airway with standard direct laryngoscopy.

Authors:  J Kavitha; Debendra Kumar Tripathy; Sandeep Kumar Mishra; Gayatri Mishra; L J Chandrasekhar; P Ezhilarasu
Journal:  Anesth Essays Res       Date:  2011 Jan-Jun

4.  The skill of tracheal intubation with rigid scopes - a randomised controlled trial comparing learning curves in 740 intubations.

Authors:  Lorenz Theiler; Robert Greif; Lukas Bütikofer; Kristopher Arheart; Maren Kleine-Brueggeney
Journal:  BMC Anesthesiol       Date:  2020-10-16       Impact factor: 2.217

5.  Evaluation of minimal dose of atracurium for cataract surgery in children: A prospective randomized double-blind study.

Authors:  Vanlal Darlong; Rakesh Garg; Ravinder Pandey; Sudarshan Khokhar; Renu Sinha; Jyotsna Punj; Rajesh Sinha
Journal:  Saudi J Anaesth       Date:  2015 Jul-Sep

6.  Effect of Low-dose Atracurium on Laryngeal Mask Airway Insertion Conditions: A Randomized Double-blind Clinical Trial.

Authors:  Karim Nasseri
Journal:  Adv Biomed Res       Date:  2017-09-21

7.  Incidence of postoperative sore throat after using a new technique of insertion of a second generation Laryngeal Mask Airway: A randomised controlled trial.

Authors:  Xiaoxiao Li; Xiuli Wang; Ye Zhao; Zhenfei Jiang; Xueli Lv; Xinrui Nie; Tong Li; Xinghe Wang; Lingyun Dai; Su Liu
Journal:  Eur J Anaesthesiol       Date:  2021-03-01       Impact factor: 4.183

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.