Literature DB >> 10903225

Comparison of esophageal pressure with pulse transit time as a measure of respiratory effort for scoring obstructive nonapneic respiratory events.

J Argod1, J L Pépin, R P Smith, P Lévy.   

Abstract

Obstructive nonapneic respiratory events (ONAREs) are much more difficult to detect and classify than apneas unless sensitive measures of respiratory effort and airflow are employed. The aim of this study was to compare two measures of respiratory effort, esophageal pressure monitoring (Pes) and pulse transit time (PTT), for scoring of ONAREs by visual analysis. Nine men (age 49 +/- 10 yr) with mild to moderate sleep apnea syndrome (AHI of 25.1 +/- 10. 8/h) were studied and 340 ONAREs (hypopneas and upper airway resistance episodes) were randomly selected for scoring by two experienced observers. Each observer blindly scored each ONARE twice (once with Pes and once with PTT) with a concurrent pneumotachography trace available for airflow quantification. This permitted the respiratory events scored with PTT to be compared with those scored with Pes, and in addition interobserver variability could be assessed for each signal. Even though standard criteria were used for scoring, there was significant interobserver variability for both Pes (29.7%) and PTT (37.1%). Taking those events for which there was agreement between the observers, PTT had a sensitivity of 79.9% and a positive predictive value of 91.2% (using Pes as the gold standard). In those ONAREs for which there was agreement between the two observers there was a larger percentage reduction in airflow compared to ONAREs that did not concur (51 versus 30.3%, p < 0.001), a larger increase in respiratory effort as assessed by PTT (slope of PTT: 23.1 versus 14. 3 arbitrary units, p < 0.01), and a higher incidence in autonomic microarousals detected with PTT (90 versus 45% of ONAREs, p < 0.006). Subtle respiratory events are more difficult to detect than apneas or frank hypopneas. When comparing PTT with esophageal pressure in detecting those events the sensitivity of PTT is good but limited when the reduction in airflow, the increase in respiratory effort, or the arousal reaction is the less clear. However, PTT appears to be a good noninvasive alternative to Pes in the detection of nonapneic obstructive respiratory events, and its ability to detect autonomic arousal gives this physiological signal added clinical usefulness.

Entities:  

Mesh:

Year:  2000        PMID: 10903225     DOI: 10.1164/ajrccm.162.1.9907086

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  15 in total

1.  Can mandibular advancement devices be a satisfactory substitute for short term use in patients on nasal continuous positive airway pressure?

Authors:  D M Smith; J R Stradling
Journal:  Thorax       Date:  2002-04       Impact factor: 9.139

2.  Pulse wave transit time for monitoring respiration rate.

Authors:  A Johansson; C Ahlstrom; T Lanne; P Ask
Journal:  Med Biol Eng Comput       Date:  2006-05-31       Impact factor: 2.602

3.  Sleep apnea syndrome: improved detection of respiratory events and cortical arousals using oxymetry pulse wave amplitude during polysomnography.

Authors:  André Zacharia; José Haba-Rubio; Raphaël Simon; Gregor John; Pascal Jordan; Alda Fernandes; Jean-Michel Gaspoz; Jean-Georges Frey; Jean-Marie Tschopp
Journal:  Sleep Breath       Date:  2008-03       Impact factor: 2.816

4.  Evidence for persistence of upper airway narrowing during sleep, 12 years after adenotonsillectomy.

Authors:  C Tasker; J H Crosby; J R Stradling
Journal:  Arch Dis Child       Date:  2002-01       Impact factor: 3.791

5.  Pulse transit time for scoring subcortical arousal in infants with obstructive sleep apnea.

Authors:  Alessandra Rizzoli; Michael S Urschitz; Judit Sautermeister; Silvia Miano; Jacopo Pagani; Maria P Villa; Christian F Poets
Journal:  Sleep Breath       Date:  2008-09-20       Impact factor: 2.816

6.  Pulse transit time in screening sleep disordered breathing in an elderly population: the PROOF-SYNAPSE study.

Authors:  Florian Chouchou; Emilia Sforza; Sébastien Celle; Vincent Pichot; Delphine Maudoux; Arnauld Garcin; Jean Claude Barthélémy; Frédéric Roche
Journal:  Sleep       Date:  2011-08-01       Impact factor: 5.849

7.  Real-time detection, classification, and quantification of apneic episodes using miniature surface motion sensors in rats.

Authors:  Dan Waisman; Lior Lev-Tov; Carmit Levy; Anna Faingersh; Ifat Colman Klotzman; Haim Bibi; Avi Rotschild; Amir Landesberg
Journal:  Pediatr Res       Date:  2015-03-31       Impact factor: 3.756

8.  Pulse transit time as a tool to characterize obstructive and central apneas in children.

Authors:  Lucie Griffon; Alessandro Amaddeo; Jorge Olmo Arroyo; Rossana Tenconi; Serena Caggiano; Sonia Khirani; Brigitte Fauroux
Journal:  Sleep Breath       Date:  2017-03-09       Impact factor: 2.816

Review 9.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

10.  Early cardiovascular abnormalities in newly diagnosed obstructive sleep apnea.

Authors:  Jean-Philippe Baguet; Marie Nadra; Gilles Barone-Rochette; Olivier Ormezzano; Hélène Pierre; Jean-Louis Pépin
Journal:  Vasc Health Risk Manag       Date:  2009-12-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.