Literature DB >> 10902559

Monte Carlo validation in diagnostic radiological imaging.

J M Boone1, M H Buonocore, V N Cooper.   

Abstract

Monte Carlo analysis in the radiological sciences has been used for several decades, however with the ever-increasing power of desktop computers, the utility of Monte Carlo simulation is increasing. A Monte Carlo code called the Simple Investigative Environment for Radiological Research Applications (SIERRA) is described mathematically, and is then compared against an array of published and unpublished results determined by other means. A series of 32 comparisons between data sets, 22 from independent Monte Carlo simulations and 10 from physically measured data, were assessed. The compared parameters included depth dose curves, lateral energy scattering profiles, scatter to primary ratios, normalized glandular doses, angular scattering distributions, and computed tomography dose index (CTDI) values. Three of the 32 comparison data sets were excluded as they were identified as outliers. Of the remaining 29 data sets compared, the mean differences ranged from -14.8% to +17.2%, and the average of the mean differences was 0.12% (sigma = 1.64%), and the median difference was 1.57%. Fifty percent of the comparisons showed mean differences of approximately 5% or less, and 93% of the comparisons showed mean differences of 12% or less. We conclude that for research applications in diagnostic radiology, the SIERRA Monte Carlo code demonstrates accuracy and precision to well within acceptable levels.

Mesh:

Year:  2000        PMID: 10902559     DOI: 10.1118/1.599007

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Task-based assessment of breast tomosynthesis: effect of acquisition parameters and quantum noise.

Authors:  I Reiser; R M Nishikawa
Journal:  Med Phys       Date:  2010-04       Impact factor: 4.071

Review 2.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

3.  The effect of skin thickness determined using breast CT on mammographic dosimetry.

Authors:  Shih-Ying Huang; John M Boone; Kai Yang; Alexander L C Kwan; Nathan J Packard
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

4.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

Authors:  W Paul Segars; Benjamin M W Tsui
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009-12       Impact factor: 10.961

5.  Experimentally determined spectral optimization for dedicated breast computed tomography.

Authors:  Nicolas D Prionas; Shih-Ying Huang; John M Boone
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 6.  Two-dimensional breast dosimetry improved using three-dimensional breast image data.

Authors:  John M Boone; Andrew M Hernandez; J Anthony Seibert
Journal:  Radiol Phys Technol       Date:  2017-06-01

7.  Dose spread functions in computed tomography: a Monte Carlo study.

Authors:  John M Boone
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

8.  Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization.

Authors:  W P Segars; Jason Bond; Jack Frush; Sylvia Hon; Chris Eckersley; Cameron H Williams; Jianqiao Feng; Daniel J Tward; J T Ratnanather; M I Miller; D Frush; E Samei
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

9.  Monte Carlo evaluation of CTD(infinity) in infinitely long cylinders of water, polyethylene and PMMA with diameters from 10 mm to 500 mm.

Authors:  Hong Zhou; John M Boone
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

10.  GPU-accelerated Monte Carlo simulation of MV-CBCT.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Dianne Ferguson; Christopher Williams; Mathias Lehmann; Paul Baturin; Pascal Huber; Rony Fueglistaller; Ingrid Valencia Lozano; Thomas Harris; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-12-02       Impact factor: 4.174

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.