Literature DB >> 10901955

Blunt abdominal trauma: comparison of ultrasonography and computed tomography in a district general hospital.

F M Abu-Zidan1, M Sheikh, F Jadallah, J A Windsor.   

Abstract

Ultrasonography has been proposed as a screening method for blunt abdominal trauma, but its specific role in comparison with other diagnostic modalities has yet to be defined. The aim of the present retrospective study was to compare the results of ultrasonography and CT of the abdomen in blunt trauma in a district general hospital. The hospital records of 25 patients who were admitted with blunt abdominal trauma to Southland Hospital, Invercargill, New Zealand, between January 1991 and November 1996 and who had both ultrasound and CT of the abdomen within 48 h of admission were reviewed. Ultrasound missed seven lesions in seven patients (7/25, 28%) compared with CT. Three of these were intestinal lesions that needed laparotomy. Ultrasound had a usefulness index of 1, 0.76, 0.72, 0.69 and 0, respectively, for detecting lesions of the kidneys, free intraperitoneal fluid, the liver, the spleen, and intestines. Although ultrasound can be used as an initial screening method for blunt abdominal trauma, CT is still the imaging modality of choice for detecting intra-abdominal lesions for stable patients in a district general hospital.

Entities:  

Mesh:

Year:  1999        PMID: 10901955     DOI: 10.1046/j.1440-1673.1999.00708.x

Source DB:  PubMed          Journal:  Australas Radiol        ISSN: 0004-8461


  6 in total

1.  The role of ultrasonography in acute appendicitis.

Authors:  F M Abu-Zidan
Journal:  World J Surg       Date:  2000-04       Impact factor: 3.352

2.  Surgeon-performed sonographic findings in a traumatic trans-anal rectal perforation.

Authors:  Fikri M Abu-Zidan; Mohamed I Abusharia; Katharina Kessler
Journal:  World J Emerg Surg       Date:  2011-08-12       Impact factor: 5.469

3.  Focussed Assessment Sonograph Trauma (FAST) and CT scan in blunt abdominal trauma: surgeon's perspective.

Authors:  Mohamed M Radwan; Fikri M Abu-Zidan
Journal:  Afr Health Sci       Date:  2006-09       Impact factor: 0.927

4.  Blunt Trauma in Paediatric Patients - Experience from a Small Centre.

Authors:  I Djordjevic; A Slavkovic; Z Marjanovic; D Zivanovic
Journal:  West Indian Med J       Date:  2015-01-28       Impact factor: 0.171

5.  Is computed tomography necessary to determine liver injury in pediatric trauma patients with negative ultrasonography?

Authors:  U Kaya; U Y Çavuş; M E Karakılıç; A B Erdem; K Aydın; B Işık; S Abacıoğlu; F Büyükcam
Journal:  Eur J Trauma Emerg Surg       Date:  2013-08-22       Impact factor: 3.693

6.  Point-of-care ultrasound in critically ill patients: Where do we stand?

Authors:  Fikri M Abu-Zidan
Journal:  J Emerg Trauma Shock       Date:  2012-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.