Literature DB >> 10900959

[Comparative in vitro studies of self-boring and self-tapping screws. Histomorphological and physical-technical studies of bone layers].

J Löhr1, N C Gellrich, P Büscher, D Wahl, B A Rahn.   

Abstract

Self-drilling screws are gaining increasing importance in maxillofacial surgery. This study assesses which screw design, self-drilling or self-tapping, is best suited to various locations of the human skull. With regard to different areas in the human midface, mandible, and cranium, the thickness of cortical bone varies as well as the relative proportion of cortical to cancellous bone. Criteria used to judge the success of screws were minimal insertion torque and minimum temperature, maximum pullout strength, and minimum deformation and destruction of the bone. To mimic the variations in anatomical conditions, 1-mm and 3-mm-thick cortical bone specimens and cancellous bone blocks were prepared. Eight screws of three types (self-tapping, self-drilling/self-tapping, conically shaped self-drilling) were inserted into the different bone specimens. Torque and temperature were measured during the insertion procedure. Subsequently, the screws were carefully removed and the specimens were processed for histological evaluation. The same insertion protocol was used to test the pull-out strength of the screws. The conically shaped screw showed best results in cancellous bone for all parameters. The self-tapping screw with a pilot hole performed best in thick cortical bone and the self-drilling/self-tapping screw performed better than did the others in thin bone. The results suggest the three screw designs to be optimal for different locations of the human skull. This project provides the data for a planned in vivo study that will evaluate the long-term influence of deformation and temperature on stability and osseointegration of the screws.

Entities:  

Mesh:

Year:  2000        PMID: 10900959     DOI: 10.1007/s100060050189

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  3 in total

1.  Experimental in vivo acute and chronic biomechanical and histomorphometrical comparison of self-drilling and self-tapping anterior cervical screws.

Authors:  Maximiliano Aguiar Porto; Patrícia Silva; Rodrigo Rosa; José Batista Volpon; Antônio Carlos Shimano; Francisco José Albuquerque de Paula; Helton Luiz Aparecido Defino
Journal:  Eur Spine J       Date:  2011-12-16       Impact factor: 3.134

2.  Osseointegrated total knee replacement connected to a lower limb prosthesis: 4 cases.

Authors:  Aditya Khemka; Laurent Frossard; Sarah J Lord; Belinda Bosley; Munjed Al Muderis
Journal:  Acta Orthop       Date:  2015-08-27       Impact factor: 3.717

3.  Osseointegrated total hip replacement connected to a lower limb prosthesis: a proof-of-concept study with three cases.

Authors:  Aditya Khemka; Chalak I FarajAllah; Sarah J Lord; Belinda Bosley; Munjed Al Muderis
Journal:  J Orthop Surg Res       Date:  2016-01-19       Impact factor: 2.359

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.