Literature DB >> 10893530

Improved estimation of velocity and flow rate using regularized three-point phase-contrast velocimetry.

A Herment1, E Mousseaux, O Jolivet, A DeCesare, F Frouin, A Todd-Pokropek, J Bittoun.   

Abstract

We improved the three-point phase-contrast method by regularization of MR velocity data after acquisition of a low velocity-to-noise ratio (VNR) velocity image and a high VNR aliased velocity image. The phase unwrapping algorithm is based on the assumed correlation of the velocity of adjacent flow voxels on the low VNR and the unaliased high VNR images. We used Fourier encoding with eight velocity-encoding gradient steps to obtain reference velocity images of the aorta from five subjects (274 images) and compared them with the phase-contrast and three-point phase-contrast images with and without regularization. The VNR of the regularized velocity image was improved by 9.1 dB and the VNR of the three-point phase-contrast velocity image was improved by 0.7 dB with respect to the low first moment velocity image. Corresponding improvements of 9 dB and 3.7 dB were obtained for the estimations of instantaneous flow rate. Magn Reson Med 44:122-128, 2000. Copyright 2000 Wiley-Liss, Inc.

Mesh:

Year:  2000        PMID: 10893530     DOI: 10.1002/1522-2594(200007)44:1<122::aid-mrm18>3.0.co;2-c

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

2.  Simultaneous Multi-VENC and Simultaneous Multi-Slice Phase Contrast Magnetic Resonance Imaging.

Authors:  Suhyung Park; Liyong Chen; Jennifer Townsend; Hyunyeol Lee; David A Feinberg
Journal:  IEEE Trans Med Imaging       Date:  2019-08-12       Impact factor: 10.048

3.  Improved SNR in phase contrast velocimetry with five-point balanced flow encoding.

Authors:  Kevin M Johnson; Michael Markl
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

4.  Multipoint 5D flow cardiovascular magnetic resonance - accelerated cardiac- and respiratory-motion resolved mapping of mean and turbulent velocities.

Authors:  Jonas Walheim; Hannes Dillinger; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2019-07-22       Impact factor: 5.364

5.  Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications.

Authors:  Maria Aristova; Jianing Pang; Yue Ma; Liliana Ma; Haben Berhane; Vitaliy Rayz; Michael Markl; Susanne Schnell
Journal:  Magn Reson Med       Date:  2022-06-26       Impact factor: 3.737

6.  Pulmonary Artery Stiffness Is Independently Associated with Right Ventricular Mass and Function: A Cardiac MR Imaging Study.

Authors:  Timothy J W Dawes; Ajay Gandhi; Antonio de Marvao; Rui Buzaco; Paweł Tokarczuk; Marina Quinlan; Giuliana Durighel; Tamara Diamond; Laura Monje Garcia; Alain de Cesare; Stuart A Cook; Declan P O'Regan
Journal:  Radiology       Date:  2016-02-24       Impact factor: 11.105

7.  Extending the dynamic range of phase contrast magnetic resonance velocity imaging using advanced higher-dimensional phase unwrapping algorithms.

Authors:  M F Salfity; J M Huntley; M J Graves; O Marklund; R Cusack; D A Beauregard