| Literature DB >> 10892596 |
A S Pereira1, K B Kenney, M S Cohen, J E Hall, J J Eron, R R Tidwell, J A Dunn.
Abstract
A HPLC-MS-MS method was developed and validated to measure lamivudine and zidovudine simultaneously in small volumes of human seminal plasma. Sample preparation was simple and rapid, requiring 25 microl of sample, the use of isotopically labeled lamivudine and zidovudine as internal standards and ultrafiltration through a molecular mass cut-off membrane. Lamivudine and its internal standard were separated from zidovudine and its internal standard with isocratic HPLC. Detection was carried out using tandem mass spectrometry. This validated method was used to analyze seminal samples obtained from six HIV-positive patients prescribed lamivudine and zidovudine.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10892596 DOI: 10.1016/s0378-4347(00)00162-6
Source DB: PubMed Journal: J Chromatogr B Biomed Sci Appl ISSN: 1387-2273