Literature DB >> 10887234

Normal and hypoplastic fetal lungs: volumetric assessment with prenatal single-shot rapid acquisition with relaxation enhancement MR imaging.

F V Coakley1, J B Lopoo, Y Lu, H Hricak, C T Albanese, M R Harrison, R A Filly.   

Abstract

PURPOSE: To determine which parameters are most closely correlated with normal fetal total lung volume and to investigate the use of these parameters in the evaluation of fetal pulmonary hypoplasia.
MATERIALS AND METHODS: Single-shot rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging was used to perform planimetric measurement of total lung volume in 46 fetuses at 18-32 weeks gestation. Total lung volume was correlated with gestational age, and biometric parameters in fetuses were correlated with normal chest findings at ultrasonography (US) (n = 24). This analysis was used to evaluate relative lung volume in fetuses suspected of having pulmonary hypoplasia (n = 22).
RESULTS: Normal fetal total lung volume was strongly correlated with liver volume measured at MR imaging (r = 0.94), fetal weight estimated at US (r = 0.93), head circumference measured at US (r = 0.90), and gestational age (r = 0.87). In fetuses suspected of having pulmonary hypoplasia, the relative lung volume varied from 4.6% to 81.6% when the observed total lung volume was expressed as a percentage of the predicted total lung volume.
CONCLUSION: Normal fetal total lung volume is strongly correlated with biometric measurements. Relative fetal lung volume can be calculated by expressing the observed volume as a percentage of the predicted volume calculated from biometric measurements; knowledge of the relative fetal lung volume assists in the confirmation and quantification of fetal pulmonary hypoplasia.

Entities:  

Mesh:

Year:  2000        PMID: 10887234     DOI: 10.1148/radiology.216.1.r00jn44107

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  16 in total

1.  Correlation between US and MRI for prenatal lung volumetry in diaphragmatic hernia, and use of Doppler to identify the ipsilateral lung cap.

Authors:  Amparo Castellote; Sandra Mencho; Elena Carreras; Teresa Higueras; Lina Cadavid; Joaquim Piqueras; Goya Enriquez
Journal:  Pediatr Radiol       Date:  2011-09-22

Review 2.  Surgery in the human fetus: the future.

Authors:  Alan W Flake
Journal:  J Physiol       Date:  2002-08-16       Impact factor: 5.182

3.  MR assessment of fetal lung development using lung volumes and signal intensities.

Authors:  Thomas M Keller; Annett Rake; Sven C A Michel; Burkhardt Seifert; Josef Wisser; Borut Marincek; Rahel A Kubik-Huch
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

Review 4.  Three- and 4-dimensional ultrasound in obstetric practice: does it help?

Authors:  Luís F Gonçalves; Wesley Lee; Jimmy Espinoza; Roberto Romero
Journal:  J Ultrasound Med       Date:  2005-12       Impact factor: 2.153

Review 5.  [MRI of the fetal abdomen].

Authors:  M Hörmann; P C Brugger; L Witzani; D Prayer
Journal:  Radiologe       Date:  2006-02       Impact factor: 0.635

6.  MRI investigation of normal fetal lung maturation using signal intensities on different imaging sequences.

Authors:  Csilla Balassy; Gregor Kasprian; Peter C Brugger; Michael Weber; Bence Csapo; Christoph Mittermayer; Marcus Hörmann; Daniela Prayer
Journal:  Eur Radiol       Date:  2006-10-03       Impact factor: 5.315

7.  Liver, meconium, haemorrhage: the value of T1-weighted images in fetal MRI.

Authors:  Jan Zizka; Pavel Elias; Karel Hodik; Jaroslav Tintera; Vera Juttnerova; Zdenek Belobradek; Ludovit Klzo
Journal:  Pediatr Radiol       Date:  2006-06-24

8.  Assessment of lung development in isolated congenital diaphragmatic hernia using signal intensity ratios on fetal MR imaging.

Authors:  Csilla Balassy; Gregor Kasprian; Peter C Brugger; Michael Weber; Bence Csapo; Christian Herold; Daniela Prayer
Journal:  Eur Radiol       Date:  2009-11-05       Impact factor: 5.315

9.  Current advances in prenatal imaging of congenital diaphragmatic [corrected] hernia.

Authors:  Beth M Kline-Fath
Journal:  Pediatr Radiol       Date:  2011-07-08

10.  [Indications and technique of fetal magnetic resonance imaging].

Authors:  U Asenbaum; P C Brugger; R Woitek; J Furtner; D Prayer
Journal:  Radiologe       Date:  2013-02       Impact factor: 0.635

View more