F V Coakley1, J B Lopoo, Y Lu, H Hricak, C T Albanese, M R Harrison, R A Filly. 1. Department of Radiology, Fetal Treatment Center, University of California San Francisco, 505 Parnassus Ave, Box 0628, L-308, San Francisco, CA 94143-0628, USA. Fergus.Coakley@radiology.ucsf.edu
Abstract
PURPOSE: To determine which parameters are most closely correlated with normal fetal total lung volume and to investigate the use of these parameters in the evaluation of fetal pulmonary hypoplasia. MATERIALS AND METHODS: Single-shot rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging was used to perform planimetric measurement of total lung volume in 46 fetuses at 18-32 weeks gestation. Total lung volume was correlated with gestational age, and biometric parameters in fetuses were correlated with normal chest findings at ultrasonography (US) (n = 24). This analysis was used to evaluate relative lung volume in fetuses suspected of having pulmonary hypoplasia (n = 22). RESULTS: Normal fetal total lung volume was strongly correlated with liver volume measured at MR imaging (r = 0.94), fetal weight estimated at US (r = 0.93), head circumference measured at US (r = 0.90), and gestational age (r = 0.87). In fetuses suspected of having pulmonary hypoplasia, the relative lung volume varied from 4.6% to 81.6% when the observed total lung volume was expressed as a percentage of the predicted total lung volume. CONCLUSION: Normal fetal total lung volume is strongly correlated with biometric measurements. Relative fetal lung volume can be calculated by expressing the observed volume as a percentage of the predicted volume calculated from biometric measurements; knowledge of the relative fetal lung volume assists in the confirmation and quantification of fetal pulmonary hypoplasia.
PURPOSE: To determine which parameters are most closely correlated with normal fetal total lung volume and to investigate the use of these parameters in the evaluation of fetal pulmonary hypoplasia. MATERIALS AND METHODS: Single-shot rapid acquisition with relaxation enhancement (RARE) magnetic resonance (MR) imaging was used to perform planimetric measurement of total lung volume in 46 fetuses at 18-32 weeks gestation. Total lung volume was correlated with gestational age, and biometric parameters in fetuses were correlated with normal chest findings at ultrasonography (US) (n = 24). This analysis was used to evaluate relative lung volume in fetuses suspected of having pulmonary hypoplasia (n = 22). RESULTS: Normal fetal total lung volume was strongly correlated with liver volume measured at MR imaging (r = 0.94), fetal weight estimated at US (r = 0.93), head circumference measured at US (r = 0.90), and gestational age (r = 0.87). In fetuses suspected of having pulmonary hypoplasia, the relative lung volume varied from 4.6% to 81.6% when the observed total lung volume was expressed as a percentage of the predicted total lung volume. CONCLUSION: Normal fetal total lung volume is strongly correlated with biometric measurements. Relative fetal lung volume can be calculated by expressing the observed volume as a percentage of the predicted volume calculated from biometric measurements; knowledge of the relative fetal lung volume assists in the confirmation and quantification of fetal pulmonary hypoplasia.
Authors: Thomas M Keller; Annett Rake; Sven C A Michel; Burkhardt Seifert; Josef Wisser; Borut Marincek; Rahel A Kubik-Huch Journal: Eur Radiol Date: 2004-03-11 Impact factor: 5.315
Authors: Csilla Balassy; Gregor Kasprian; Peter C Brugger; Michael Weber; Bence Csapo; Christoph Mittermayer; Marcus Hörmann; Daniela Prayer Journal: Eur Radiol Date: 2006-10-03 Impact factor: 5.315
Authors: Jan Zizka; Pavel Elias; Karel Hodik; Jaroslav Tintera; Vera Juttnerova; Zdenek Belobradek; Ludovit Klzo Journal: Pediatr Radiol Date: 2006-06-24
Authors: Csilla Balassy; Gregor Kasprian; Peter C Brugger; Michael Weber; Bence Csapo; Christian Herold; Daniela Prayer Journal: Eur Radiol Date: 2009-11-05 Impact factor: 5.315