Literature DB >> 10882444

Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: a prospective computed tomography-controlled study.

C Fink1, K P Benedetto, W Hackl, C Hoser, M C Freund, M Rieger.   

Abstract

PURPOSE: It was the purpose of the study to evaluate a new polyglyconate bioabsorbable interference screw for graft fixation in anterior cruciate ligament (ACL) reconstruction. TYPE OF STUDY: Prospective randomized.
MATERIALS AND METHODS: Forty patients who underwent endoscopic ACL reconstruction were included in the study and randomized intraoperatively. Group A consisted of 20 patients (6 women, 14 men; mean age, 29.6 years) who had femoral bone block fixation with a bioabsorbable interference screw and tibial fixation with a titanium interference screw. Group B included 20 patients (5 women, 15 men; mean age 29.6 years) who had fixation of both femoral and tibial bone blocks with titanium interference screws. There was no significant difference between the groups with regard to age, gender, height, weight, time from injury to surgery, activity level, and concomitant injuries.
RESULTS: Clinical results (using IKDC, Lysholm, Tegner scores) of the 2 groups as well as instrumented laxity measurements (KT-1000) did not show significant (P >.05) differences at any stage of follow-up. No complications with respect to graft fixation could be found. Computed tomography scans, performed within the first postoperative week, at 6 weeks, and at 3, 6, 12, and 24 months postoperatively revealed a uniform picture for all patients within the groups, showing completed screw degradation at 12 months in group A.
CONCLUSION: Polyglyconate interference screw fixation for patellar tendon grafts has not been found to be associated with increased clinical complications or significant osteolysis. It provided equivalent fixation and clinical results compared with titanium screws. However, replacement of the screw with bone did not take place for up to 3 years postoperatively.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10882444     DOI: 10.1053/jars.2000.4633

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  18 in total

1.  Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb.

Authors:  Myung Chul Lee; Hyunchul Jo; Tae-Soo Bae; Jin Dae Jang; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-03-06       Impact factor: 4.342

2.  [ACL reconstruction with bone-patellar tendon-bone graft and proximal fixation with the EndoButton: a 2- to 5-year follow-up].

Authors:  K Tecklenburg; C Hoser; R Sailer; J Oberladstätter; C Fink
Journal:  Unfallchirurg       Date:  2005-09       Impact factor: 1.000

Review 3.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

4.  Meta-analysis comparing bioabsorbable versus metal interference screw for adverse and clinical outcomes in anterior cruciate ligament reconstruction.

Authors:  Pat Laupattarakasem; Malinee Laopaiboon; Weerachai Kosuwon; Wiroon Laupattarakasem
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-12-14       Impact factor: 4.342

Review 5.  Migration of "bioabsorbable" screws in ACL repair. How much do we know? A systematic review.

Authors:  Hélder Pereira; Hélder M D Pereira; Vítor M Correlo; Joana Silva-Correia; Joaquim M Oliveira; Rui L Reis; Rui L Reis Ceng; João Espregueira-Mendes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-03       Impact factor: 4.342

6.  Failure strength of bioabsorbable interference screws: effects of in vivo degradation for 12 weeks.

Authors:  Onder Kilicoglu; Mehmet Demirhan; Senol Akman; Ata Can Atalar; Serhat Ozsoy; Umit Ince
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-05-08       Impact factor: 4.342

7.  Painful knee joint after ACL reconstruction using biodegradable interference screws- SPECT/CT a valuable diagnostic tool? A case report.

Authors:  Michael T Hirschmann; Tom Adler; Helmut Rasch; Rolf W Hügli; Niklaus F Friederich; Markus P Arnold
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2010-09-16

Review 8.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

9.  Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction.

Authors:  K-H Frosch; T Sawallich; G Schütze; A Losch; T Walde; P Balcarek; F Konietschke; K M Stürmer
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-08-21

Review 10.  Femoral fracture following knee ligament reconstruction surgery due to an unpredictable complication of bioabsorbable screw fixation: a case report and review of literature.

Authors:  Sujith Konan; Fares Sami Haddad
Journal:  J Orthop Traumatol       Date:  2009-12-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.