Literature DB >> 10874802

Lethal photosensitization, autogenous bone, and e-PTFE membrane for the treatment of peri-implantitis: preliminary results.

R Haas1, M Baron, O Dörtbudak, G Watzek.   

Abstract

This clinical study reports on the results of a new method in the treatment of peri-implantitis. The surfaces of 24 plasma flame-sprayed cylindric implants in 17 patients who were diagnosed with peri-implantitis were decontaminated with a combination of toluidine blue (100 micrograms/mL) and laser irradiation at a wavelength of 906 nm. Bone defects were filled with autogenous bone using e-PTFE membranes for retention of the grafting material. Premature membrane exposure occurred in all patients after an average of 3 weeks (+/- 10 days), which required immediate removal of the exposed membrane in 1 patient. Since the soft tissue showed minimal signs of inflammation, the membranes were left in situ for another 6 weeks in all other patients. The mean radiographic peri-implant bone gain was 2 mm +/- 1.90 mm after 9.5 months (maxilla 2.5 mm +/- 2.38 mm; mandible 1.9 mm +/- 1.87 mm). Two implants around which the initial bone defect had already reached the basket had to be removed after 10 months and 35 months, respectively, despite radiographic evidence of improvement of the peri-implant defect. The longer the membrane stayed in situ, the more bone was gained, as long as the membrane was covered by soft tissue (P = .01). However, the longer an exposed membrane was left in place, the smaller the resultant bone gain (P = .0001). Therefore, despite the absence of clinical signs of inflammation, exposed membranes should be removed immediately. The short-term results of this study corroborate the efficacy of the applied treatment method in prolonging the service time of dental implants involved with peri-implantitis.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10874802

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  22 in total

Review 1.  Oral microbial biofilms and plaque-related diseases: microbial communities and their role in the shift from oral health to disease.

Authors:  Ludovico Sbordone; Claudia Bortolaia
Journal:  Clin Oral Investig       Date:  2003-11-04       Impact factor: 3.573

Review 2.  Interventions for replacing missing teeth: treatment of peri-implantitis.

Authors:  Marco Esposito; Maria Gabriella Grusovin; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2012-01-18

Review 3.  Laser phototherapy in the treatment of periodontal disease. A review.

Authors:  Carlos de Paula Eduardo; Patricia Moreira de Freitas; Marcella Esteves-Oliveira; Ana Cecília Corrêa Aranha; Karen Müller Ramalho; Alyne Simões; Marina Stella Bello-Silva; Jan Tunér
Journal:  Lasers Med Sci       Date:  2010-07-17       Impact factor: 3.161

Review 4.  Laser applications in oral surgery and implant dentistry.

Authors:  Herbert Deppe; Hans-Henning Horch
Journal:  Lasers Med Sci       Date:  2007-02-01       Impact factor: 3.161

5.  Efficacy of Antimicrobial Photodynamic Therapy as an Adjunctive to Mechanical Debridement in the Treatment of Peri-implant Diseases: A Randomized Controlled Clinical Trial.

Authors:  Mohammad Reza Karimi; Ali Hasani; Salva Khosroshahian
Journal:  J Lasers Med Sci       Date:  2016-07-18

6.  Evaluation of dental pulp temperature rise during photo-activated decontamination (PAD) of caries: an in vitro study.

Authors:  Samir Nammour; T Zeinoun; I Bogaerts; M Lamy; S O Geerts; S Bou Saba; L Lamard; A Peremans; M Limme
Journal:  Lasers Med Sci       Date:  2009-06-02       Impact factor: 3.161

7.  Photodynamic therapy as an adjunctive treatment for chronic periodontitis: a meta-analysis.

Authors:  Momen A Atieh
Journal:  Lasers Med Sci       Date:  2009-12-19       Impact factor: 3.161

8.  The effects of Er:YAG on the treatment of peri-implantitis: a meta-analysis of randomized controlled trials.

Authors:  Mingdong Yan; Miaomiao Liu; Min Wang; Fengying Yin; Haibin Xia
Journal:  Lasers Med Sci       Date:  2014-11-27       Impact factor: 3.161

9.  The utilization of a diode laser in the surgical treatment of peri-implantitis. A randomized clinical trial.

Authors:  Christos A Papadopoulos; Ioannis Vouros; Georgios Menexes; Antonis Konstantinidis
Journal:  Clin Oral Investig       Date:  2015-01-28       Impact factor: 3.573

10.  Evaluation of Effectiveness of Photodynamic Therapy With Low-level Diode Laser in Nonsurgical Treatment of Peri-implantitis.

Authors:  Ehsan Birang; Mohammad Reza Talebi Ardekani; Mahboobeh Rajabzadeh; Gloria Sarmadi; Reza Birang; Norbert Gutknecht
Journal:  J Lasers Med Sci       Date:  2017-06-27
View more