Literature DB >> 10857833

Hyperopic laser in situ keratomileusis with the Nidek EC-5000 excimer laser.

D Zadok1, G Maskaleris, M Montes, S Shah, V Garcia, A Chayet.   

Abstract

OBJECTIVE: To evaluate the efficacy, safety, and predictability of hyperopic laser in situ keratomileusis (H-LASIK) using modified software.
DESIGN: Retrospective, noncomparative case series. PARTICIPANTS: The first 72 consecutive eyes of 44 patients with up to +5.00 diopters (D) hyperopia. INTERVENTION: Hyperopic LASIK using the Automatic Corneal Shaper (ACS; Chiron Vision, Claremont, CA) and the Nidek EC-5000 excimer laser (Nidek, Tokyo, Japan). MAIN OUTCOME MEASURES: Uncorrected visual acuity, manifest spherical equivalent (MSE), best-corrected visual acuity (BCVA), and complications were studied.
RESULTS: At 6 months, in the low hyperopia group (<3.00 D), mean MSE was +0.30 +/- 0.71 D, with 88.9% eyes within 1 D of emmetropia compared with +1.09 +/- 0.92 D and 51.8% within 1 D of emmetropia in the moderate hyperopia group (> or =3.00 D; P = 0.003). Uncorrected visual acuity was 20/40 or better in 43 of 45 eyes (95.6%) and in 21 of 27 (77.8%) eyes in the low and moderate hyperopia groups, respectively. Only one eye (1.4%) from the moderate hyperopia group lost two lines of BCVA. Eighteen eyes (25%) required retreatment to correct residual hyperopia, 9 eyes (20.0%) in the low hyperopia group and 9 eyes (33.3%) in the moderate hyperopia group. Retreatments resulted in an MSE of +0.02 +/- 0.45 D and +0.04 +/- 0.73 D in the low and moderate hyperopia groups, respectively. No flap-related complications were seen.
CONCLUSIONS: Hyperopic LASIK with the ACS and the Nidek EC-5000 excimer laser using our modified software is a safe, effective, and predictable procedure for low hyperopia. Results are satisfactory up to moderate hyperopia. Significant regression can occur for low and moderate hyperopia. Retreatment can be performed safely and effectively to improve the visual and refractive results.

Entities:  

Mesh:

Year:  2000        PMID: 10857833     DOI: 10.1016/s0161-6420(00)00097-x

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  6 in total

1.  The surgical correction of moderate hypermetropia: the management controversy.

Authors:  C N McGhee; S Ormonde; T Kohnen; M Lawless; A Brahma; I Comaish
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

2.  Conductive keratoplasty: a radiofrequency-based technique for the correction of hyperopia.

Authors:  Marguerite B McDonald
Journal:  Trans Am Ophthalmol Soc       Date:  2005

3.  3-Year follow-up after Lasik: assessing the risk factors for retreatment.

Authors:  Jorge E Valdez-García; Julio C Hernandez-Camarena; Rosa Martínez-Muñoz
Journal:  Int Ophthalmol       Date:  2015-05-19       Impact factor: 2.031

4.  [Laser in situ keratomileusis for correction of hyperopia and hyperopic astigmatism using a scanning spot excimer laser. Results of a prospective clinical study after 1 year].

Authors:  T Kohnen; A Mirshahi; M Cichocki; J Bühren; G W K Steinkamp
Journal:  Ophthalmologe       Date:  2003-12       Impact factor: 1.059

5.  Assessment of refractive outcome of femtosecond-assisted LASIK for hyperopia correction.

Authors:  Mohamed Tarek El-Naggar; Dikran Gilbert Hovaghimian
Journal:  Electron Physician       Date:  2017-03-25

6.  Femtosecond-LASIK outcomes using the VisuMax®-MEL® 80 platform for hyperopia and hyperopic astigmatism refractive surgery.

Authors:  Bogdana Tăbăcaru; Horia Tudor Stanca; Ruxandra Angela Pîrvulescu; Simona Stanca; Ciprian Danielescu; Mihnea Munteanu; Cosmin Roșca; Adrian Cosmin Teodoru
Journal:  Exp Ther Med       Date:  2021-01-26       Impact factor: 2.447

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.