Implementation of enhanced dynamic wedge in the focus rtp system.

M Miften1, M Wiesmeyer, A Beavis, K Takahashi, S Broad.   

Abstract

The FOCUS RTP system implementation of Varian's enhanced dynamic wedge (EDW) is presented. Calculations of both dose distributions and wedge factors (WFs) are based on segmented treatment tables (STTs). Calculating dose requires a "transmission matrix" derived from an STT to model the modified fluence from the source. The dose calculation is then performed using either the Clarkson or convolution/superposition algorithms. An initial "primary dose/monitor unit (MU) fraction" WF estimate at the weight point of symmetric and asymmetric fields is calculated from the STT as the ratio of MU delivered on the axis of the weight point divided by total MU delivered for the treatment field. In our approach, we go beyond this initial estimate with a "scatter dose" correction. This requires measured 60 degrees WFs for 5 fields. Scatter corrections derived from measured WFs are interpolated for other wedge angles and field sizes in much the same way as arbitrary wedge angle STTs are derived from a "golden STT" using the "ratio of tangents" formalism. Dose comparisons with measured distributions show good agreement to within 3% or 3 mm for 6-MV beams and all EDW angles. Agreement with measurements to within 1% is obtained for WFs in all symmetric and asymmetric fields for 6- and 10-MV beams. For large wedge angles and field sizes, this represents a significant improvement over the 3% to 4% errors often observed using the MU fraction model alone.

Entities:  

Mesh:

Year:  2000        PMID: 10856686     DOI: 10.1016/s0958-3947(00)00033-9

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  5 in total

1.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

2.  Analytical correction of an extension of the "MU Fraction Approximation" for Varian enhanced dynamic wedges.

Authors:  Michael S Gossman; Subhash C Sharma
Journal:  J Med Phys       Date:  2010-04

3.  Linear array measurements of enhanced dynamic wedge and treatment planning system (TPS) calculation for 15 MV photon beam and comparison with electronic portal imaging device (EPID) measurements.

Authors:  Borislava Petrovic; Aleksandra Grzadziel; Laza Rutonjski; Krzysztof Slosarek
Journal:  Radiol Oncol       Date:  2010-09-09       Impact factor: 2.991

4.  The accuracy of dynamic wedge dose computation in the ADAC Pinnacle RTP system.

Authors:  H Shao; X Wu; C Luo; A Crooks; A Bernstein; A Markoe
Journal:  J Appl Clin Med Phys       Date:  2004-10-01       Impact factor: 2.102

5.  Enhanced dynamic wedge output factors for Varian 2300CD and the case for a reference database.

Authors:  Christopher F Njeh
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.