Literature DB >> 10854882

Influence of load carrying on loads in internal spinal fixators.

A Rohlmann1, F Graichen, G Bergmann.   

Abstract

After spinal stabilization with an implant, patients want to know whether carrying loads will endanger their spine and their implant. Therefore, the effect of carrying a weight on the loading of internal spinal fixation devices was determined in 10 patients using instrumented, telemeterized internal fixators. Patients carried a 5kg dumbbell in one hand as well as up to 20kg in both hands. Compared to normal standing carrying a weight caused only a slight increase of the fixator loads in all patients. The maximum flexion bending moment in the fixators was then lower than during walking. Carrying a weight even decreased the axial compression force in the fixators of the patients with the T11 or T12 vertebra bridged. Patients also raised their arms in anteversion while holding weights of up to 5kg with both hands. This increased the flexion bending moment in the fixators. Only a small part of a carried weight is taken over by internal fixators. Carrying a shopping bag only slightly increases the risk of pedicle screw breakage, however, since the spine has to support most of the additional weight, it represents a risk with regard to correction loss and bone sintering.

Entities:  

Mesh:

Year:  2000        PMID: 10854882     DOI: 10.1016/s0021-9290(00)00075-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  7 in total

1.  Effect of augmentation techniques on the failure of pedicle screws under cranio-caudal cyclic loading.

Authors:  Richard Bostelmann; Alexander Keiler; Hans Jakob Steiger; Armin Scholz; Jan Frederick Cornelius; Werner Schmoelz
Journal:  Eur Spine J       Date:  2015-03-27       Impact factor: 3.134

Review 2.  Basic concepts in metal work failure after metastatic spine tumour surgery.

Authors:  Naresh Kumar; Ravish Patel; Anshuja Charvi Wadhwa; Aravind Kumar; Helena Maria Milavec; Dhiraj Sonawane; Gurpal Singh; Lorin Michael Benneker
Journal:  Eur Spine J       Date:  2017-12-04       Impact factor: 3.134

3.  Timing of PMMA cement application for pedicle screw augmentation affects screw anchorage.

Authors:  Werner Schmoelz; Christian Heinz Heinrichs; Sven Schmidt; Angel R Piñera; Felix Tome-Bermejo; Javier M Duart; Marlies Bauer; Luis Álvarez Galovich
Journal:  Eur Spine J       Date:  2017-04-03       Impact factor: 3.134

4.  Monitoring the load on a telemeterised vertebral body replacement for a period of up to 65 months.

Authors:  A Rohlmann; M Dreischarf; T Zander; F Graichen; P Strube; H Schmidt; G Bergmann
Journal:  Eur Spine J       Date:  2013-10-17       Impact factor: 3.134

5.  Anterior thoracic posture increases thoracolumbar disc loading.

Authors:  Deed E Harrison; Christopher J Colloca; Donald D Harrison; Tadeusz J Janik; Jason W Haas; Tony S Keller
Journal:  Eur Spine J       Date:  2004-05-27       Impact factor: 3.134

6.  Activities of everyday life with high spinal loads.

Authors:  Antonius Rohlmann; David Pohl; Alwina Bender; Friedmar Graichen; Jörn Dymke; Hendrik Schmidt; Georg Bergmann
Journal:  PLoS One       Date:  2014-05-27       Impact factor: 3.240

7.  Effect of pedicle screw augmentation with a self-curing elastomeric material under cranio-caudal cyclic loading-a cadaveric biomechanical study.

Authors:  Werner Schmoelz; Alexander Keiler; Marko Konschake; Richard A Lindtner; Alessandro Gasbarrini
Journal:  J Orthop Surg Res       Date:  2018-10-11       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.