H Nishi1, S Nishimura, M Higashiura, N Ikeya, H Ohta, T Tsuji, M Nishimura, S Ohnishi, H Higashi.
Abstract
A new method for evaluating histamine release from purified basophils was developed. Basophil-containing leukocytes were directly purified from a small amount of peripheral blood using monoclonal antibody BA312-coated magnetic beads. The purified basophils still rosetted to magnetic beads maintained a normal response to anti-IgE and to dust mite allergen in comparison with the conventional method using washed leukocytes. This methodology facilitates the purification of basophils, anti-IgE- and allergen-induced histamine release, and subsequent histamine determination within only 3 h. The released histamine was analyzed by an enzyme-linked immunosorbent assay (ELISA) with a characteristic detection profile. Since all steps were performed in 96-well microplates, many clinical samples could be analyzed at the same time, permitting easy applications in routine laboratories.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10854599 DOI: 10.1016/s0022-1759(00)00169-1