Determination of stroke volume by means of electrical impedance tomography.

A Vonk-Noordegraaf1, A Janse, J T Marcus, J G Bronzwaer, P E Postmust, T J Faes, P M De Vries.   

Abstract

ECG-gated electrical impedance tomography (EIT) is a non-invasive imaging technique, developed to monitor blood volume changes. This study is the first in comparing this non-invasive technique in measuring stroke volume with established techniques. The objective of this study was to validate EIT variables derived from the EIT images with paired obtained stroke volume measurements by thermodilution and MRI. After right cardiac catheterization, EIT measurements were performed in 25 patients. Regression analysis was used to analyse the relation between the EIT results and stroke volume determined by thermodilution. From the regression line an equation was derived to estimate stroke volume (in ml) by EIT. A strong correlation was found between EIT and stroke volume measured by the thermodilution method (r = 0.86). In a group of 11 healthy subjects this equation was validated to MRI. The mean and standard deviation of the difference between EIT and MRI was 0.7 ml and 5.4 ml respectively. These data indicate that EIT is a valid and reproducible method for the assessment of stroke volume.

Entities:  

Mesh:

Year:  2000        PMID: 10847195     DOI: 10.1088/0967-3334/21/2/308

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  10 in total

1.  Determinants of pulmonary perfusion measured by electrical impedance tomography.

Authors:  Henk J Smit; Anton Vonk Noordegraaf; J Tim Marcus; Anco Boonstra; Peter M de Vries; Pieter E Postmus
Journal:  Eur J Appl Physiol       Date:  2004-02-21       Impact factor: 3.078

2.  EIT image reconstruction with four dimensional regularization.

Authors:  Tao Dai; Manuchehr Soleimani; Andy Adler
Journal:  Med Biol Eng Comput       Date:  2008-07-17       Impact factor: 2.602

3.  On the Measurement of Electrical Impedance Spectroscopy (EIS) of the Human Head.

Authors:  Giorgio Bonmassar; Sunao Iwaki; Gregory Goldmakher; Leonardo M Angelone; John W Belliveau; Michael H Lev
Journal:  Int J Bioelectromagn       Date:  2010-01-01

4.  Increasing Veno-Arterial Extracorporeal Membrane Oxygenation Flow Reduces Electrical Impedance of the Lung Regions in Porcine Acute Heart Failure.

Authors:  M Popková; E Kuriščák; P Hála; D Janák; L Tejkl; J Bělohlávek; P Ošťádal; P Neužil; O Kittnar; M Mlček
Journal:  Physiol Res       Date:  2020-06-25       Impact factor: 1.881

5.  Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography.

Authors:  Caroline A Grant; Trang Pham; Judith Hough; Thomas Riedel; Christian Stocker; Andreas Schibler
Journal:  Crit Care       Date:  2011-01-25       Impact factor: 9.097

Review 6.  Electrical Impedance Tomography for Cardio-Pulmonary Monitoring.

Authors:  Christian Putensen; Benjamin Hentze; Stefan Muenster; Thomas Muders
Journal:  J Clin Med       Date:  2019-08-07       Impact factor: 4.241

Review 7.  Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions.

Authors:  Elena Spinelli; Tommaso Mauri; Alberto Fogagnolo; Gaetano Scaramuzzo; Annalisa Rundo; Domenico Luca Grieco; Giacomo Grasselli; Carlo Alberto Volta; Savino Spadaro
Journal:  BMC Anesthesiol       Date:  2019-08-07       Impact factor: 2.217

8.  Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model.

Authors:  Anneli Fagerberg; Ola Stenqvist; Anders Aneman
Journal:  Crit Care       Date:  2009-03-05       Impact factor: 9.097

9.  Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers.

Authors:  Fabian Braun; Martin Proença; Andy Adler; Thomas Riedel; Jean-Philippe Thiran; Josep Solà
Journal:  PLoS One       Date:  2018-01-26       Impact factor: 3.240

Review 10.  Challenges to the Application of Integrated, Personalized Care for Patients with COPD-A Vision for the Role of Clinical Information.

Authors:  Lowie E G W Vanfleteren; Alex J van 't Hul; Katarzyna Kulbacka-Ortiz; Anders Andersson; Anders Ullman; Martin Ingvar
Journal:  J Clin Med       Date:  2020-05-02       Impact factor: 4.241

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.