Literature DB >> 10841422

Saturation current and collection efficiency for ionization chambers in pulsed beams.

F DeBlois1, C Zankowski, E B Podgorsak.   

Abstract

Saturation currents and collection efficiencies in ionization chambers exposed to pulsed megavoltage photon and electron beams are determined assuming a linear relationship between 1/I and 1/V in the extreme near-saturation region, with I and V the chamber current and polarizing voltage, respectively. Careful measurements of chamber current against polarizing voltage in the extreme near-saturation region reveal a current rising faster than that predicted by the linear relationship. This excess current combined with conventional "two-voltage" technique for determination of collection efficiency may result in an up to 0.7% overestimate of the saturation current for standard radiation field sizes of 10X10 cm2. The measured excess current is attributed to charge multiplication in the chamber air volume and to radiation-induced conductivity in the stem of the chamber (stem effect). These effects may be accounted for by an exponential term used in conjunction with Boag's equation for collection efficiency in pulsed beams. The semiempirical model follows the experimental data well and accounts for both the charge recombination as well as for the charge multiplication effects and the chamber stem effect.

Entities:  

Mesh:

Year:  2000        PMID: 10841422     DOI: 10.1118/1.598992

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Addendum to the AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon beams.

Authors:  Malcolm McEwen; Larry DeWerd; Geoffrey Ibbott; David Followill; David W O Rogers; Stephen Seltzer; Jan Seuntjens
Journal:  Med Phys       Date:  2014-04       Impact factor: 4.071

2.  Fidelity of dose delivery at high dose rate of volumetric modulated arc therapy in a truebeam linac with flattening filter free beams.

Authors:  Georgios Kalantzis; Jianguo Qian; Bin Han; Gary Luxton
Journal:  J Med Phys       Date:  2012-10

3.  The challenge of ionisation chamber dosimetry in ultra-short pulsed high dose-rate Very High Energy Electron beams.

Authors:  M McManus; F Romano; N D Lee; W Farabolini; A Gilardi; G Royle; H Palmans; A Subiel
Journal:  Sci Rep       Date:  2020-06-03       Impact factor: 4.379

4.  Ultrahigh dose rate pencil beam scanning proton dosimetry using ion chambers and a calorimeter in support of first in-human FLASH clinical trial.

Authors:  Eunsin Lee; Ana Mónica Lourenço; Joseph Speth; Nigel Lee; Anna Subiel; Francesco Romano; Russell Thomas; Richard A Amos; Yongbin Zhang; Zhiyan Xiao; Anthony Mascia
Journal:  Med Phys       Date:  2022-07-14       Impact factor: 4.506

5.  Development of an ultra-thin parallel plate ionization chamber for dosimetry in FLASH radiotherapy.

Authors:  Faustino Gómez; Diego M Gonzalez-Castaño; Nicolás Gómez Fernández; Juan Pardo-Montero; Andreas Schüller; Alessia Gasparini; Verdi Vanreusel; Dirk Verellen; Giuseppe Felici; Rafael Kranzer; Jose Paz-Martín
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

6.  Study of the uncertainty in the determination of the absorbed dose to water during external beam radiotherapy calibration.

Authors:  Pablo Castro; Feliciano García-Vicente; Cristina Mínguez; Alejandro Floriano; David Sevillano; Leopoldo Pérez; Juan J Torres
Journal:  J Appl Clin Med Phys       Date:  2008-01-22       Impact factor: 2.102

7.  Ion recombination corrections of ionization chambers in flattening filter-free photon radiation.

Authors:  Yuenan Wang; Stephen B Easterling; Joseph Y Ting
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.