Monte Carlo calculations and experimental measurements of dosimetry parameters of a new 103Pd source.

Z Li1, J R Palta, J J Fan.   

Abstract

Permanent prostate implantation using 125I (iodine) or 103Pd (palladium) sources is a popular treatment option in the management of early prostate cancer. As sources of new designs are developed and marketed for application in permanent prostate implantations, their dosimetric characteristics must be carefully determined in order to maintain the accuracy of patient treatment. This report presents the results of experimental measurements and Monte Carlo calculations of the dosimetric parameters performed for a newly available 103Pd seed source. The measurements were performed in a large scanning water phantom using a diode detector. The positioning of the source and detector was achieved by a computer-controlled positioning mechanism in the scanning water phantom. The dose rate constant in water for the new 103Pd source was determined from measurements with the diode detector calibrated with 125I sources of known air-kerma strength. The radial dose function values for the source were measured using the diode detector. Monte Carlo photon transport calculations were then used to calculate the dosimetric parameters of dose rate constant, radial dose function, and anisotropy function using an accurate geometric model of the source. The measured dose rate constant of 0.693 cGy/U-hr compares well with the Monte Carlo calculated value of 0.677 cGy/U-hr. These results are further compared with data on existing 103Pd sources.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10841416     DOI: 10.1118/1.598975

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  A comparison study on various low energy sources in interstitial prostate brachytherapy.

Authors:  Mahdi Bakhshabadi; Mahdi Ghorbani; Mohsen Khosroabadi; Courtney Knaup; Ali S Meigooni
Journal:  J Contemp Brachytherapy       Date:  2016-02-05

2.  Monte Carlo investigation of energy response of various detector materials in ¹²⁵I and ¹⁶⁹Yb brachytherapy dosimetry.

Authors:  T Palani Selvam; Biju Keshavkumar
Journal:  J Appl Clin Med Phys       Date:  2010-07-28       Impact factor: 2.102

3.  Thermoluminescent and Monte Carlo dosimetry of IR06-103Pd brachytherapy source.

Authors:  Pooneh Saidi; Mahdi Sadeghi; S Hamed Hosseini; Claudio Tenreiro
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

4.  Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources.

Authors:  Mozaffari A; Ghorbani M
Journal:  J Biomed Phys Eng       Date:  2019-08-01

5.  Monte Carlo dosimetric characterization of the IsoAid ADVANTAGE 103Pd brachytherapy source.

Authors:  Keith T Sowards
Journal:  J Appl Clin Med Phys       Date:  2007-03-20       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.