Literature DB >> 10841415

High resolution computed tomography and MRI for monitoring lung tumor growth in mice undergoing radioimmunotherapy: correlation with histology.

S J Kennel1, I A Davis, J Branning, H Pan, G W Kabalka, M J Paulus.   

Abstract

A model lung tumor system has been developed in mice for the evaluation of vascular targeted radioimmunotherapy. In this model, EMT-6 mammary carcinoma tumors growing in the lung are treated with 213Bi, an alpha particle emitter, which is targeted to lung blood vessels using a monoclonal antibody. Smaller tumors (< 100 microm in diameter) are cured, but larger tumors undergo a period of regression and then regrow and ultimately prove lethal. The goal of this work was to determine if external imaging with MRI or CT could be used routinely to monitor the growth/ regression of lung tumors in live mice. To attempt to evaluate individual tumors in vivo, animals were initially imaged with magnetic resonance imaging (MRI). High resolution MRI images could be obtained only after sacrifice when lungs were not moving. In contrast, high resolution computed tomography (CT) produced evaluable images from anesthetized animals. Serial CT images (up to 5/animal) were collected over a 17 day period of tumor growth and treatment. When tumored animals became moribund, animals were sacrificed and lungs were inflated with fixative, embedded in paraffin, and then sectioned serially to compare the detection of tumors by high resolution CT with detection by histology. CT proved most useful in detecting lung tumors located in the hilar area and least useful in detecting serosal surface and anterior lobe tumor foci. Overall, CT images of live animals revealed tumors in approximately 2/3 of cases detected in histologic serial sections when relatively few tumors were present per lung. Detection of lesions and their resolution post therapy were complicated due to residual hemorrhagic, regressing tumor nodules and the development of lung edema both of which appeared as high density areas in the CT scans. We conclude that the microCT method used could identify some lung tumors as small as 100 microm in diameter; however, no concrete evaluation of therapy induced regression of the tumors could be made with CT analyses alone.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10841415     DOI: 10.1118/1.598974

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

Review 1.  Preclinical development of molecular-targeted agents for cancer.

Authors:  Alberto Ocana; Atanasio Pandiella; Lillian L Siu; Ian F Tannock
Journal:  Nat Rev Clin Oncol       Date:  2010-12-07       Impact factor: 66.675

2.  Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging.

Authors:  Susanne Greschus; Fabian Kiessling; Matthias P Lichy; Jens Moll; Margareta M Mueller; Rajkumar Savai; Frank Rose; Clemens Ruppert; Andreas Günther; Marcus Luecke; Norbert E Fusenig; Wolfhard Semmler; Horst Traupe
Journal:  Neoplasia       Date:  2005-08       Impact factor: 5.715

Review 3.  Small animal imaging facility: new perspectives for the radiologist.

Authors:  R Grassi; C Cavaliere; S Cozzolino; L Mansi; S Cirillo; G Tedeschi; R Franchi; P Russo; S Cornacchia; A Rotondo
Journal:  Radiol Med       Date:  2008-12-11       Impact factor: 3.469

4.  In vivo microCT imaging of rodent cerebral vasculature.

Authors:  Youngho Seo; Tomoki Hashimoto; Yoshitsugu Nuki; Bruce H Hasegawa
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

5.  Photodynamic therapy of disseminated non-small cell lung carcinoma in a murine model.

Authors:  Craig E Grossman; Stephen Pickup; Amy Durham; E Paul Wileyto; Mary E Putt; Theresa M Busch
Journal:  Lasers Surg Med       Date:  2011-09       Impact factor: 4.025

6.  Micro-CT with respiratory and cardiac gating.

Authors:  C Badea; L W Hedlund; G A Johnson
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

7.  Contrast agents for quantitative microCT of lung tumors in mice.

Authors:  Kush Lalwani; Anand Giddabasappa; Danan Li; Peter Olson; Brett Simmons; Farbod Shojaei; Todd Van Arsdale; James Christensen; Amy Jackson-Fisher; Anthony Wong; Patrick B Lappin; Jeetendra Eswaraka
Journal:  Comp Med       Date:  2013       Impact factor: 0.982

8.  High-resolution X-ray microtomography for the detection of lung tumors in living mice.

Authors:  Nora M De Clerck; Kris Meurrens; Horst Weiler; Dirk Van Dyck; Greet Van Houtte; Piter Terpstra; Andrei A Postnov
Journal:  Neoplasia       Date:  2004 Jul-Aug       Impact factor: 5.715

9.  A process model for direct correlation between computed tomography and histopathology application in lung cancer.

Authors:  Jessica C Sieren; Jamie Weydert; Eman Namati; Jacqueline Thiesse; Jered P Sieren; Joseph M Reinhardt; Eric A Hoffman; Geoffrey McLennan
Journal:  Acad Radiol       Date:  2010-02       Impact factor: 3.173

10.  A new method for respiratory gating during microcomputed tomography of lung in mice.

Authors:  Evan M Johnson; Roger E Price; Jonathan M Kurie; Belinda S Rivera; Dianna D Cody
Journal:  J Am Assoc Lab Anim Sci       Date:  2008-07       Impact factor: 1.232

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.