| Literature DB >> 1083841 |
A L Carsten, V P Bond, K Thompson.
Abstract
The spleen-colony technique has been used for determining the relative biological effectiveness (r.b.e.) for several energies of neutron radiation. Donor mice were exposed for fission and accelerator-generated neutrons at a variety of doses and energies. Immediately after exposure, donor bone-marrow was removed from the hind legs, and standard amounts were injected intravenously into lethally X-irradiated recipients. After 7 days the recipients spleens were evaluated for surface colonies. Dose-response curves were obtained for each type of radiation and the Do was determined. The neutron r.b.e. values from the Do compared with 250kVp X-rays were: reactor 1.58, 252Cf 1:59, and accelerator varied from 2.85 at 1.0 Mev to 0.85 at 13.4 MeV.Entities:
Mesh:
Substances:
Year: 1976 PMID: 1083841 DOI: 10.1080/09553007614551561
Source DB: PubMed Journal: Int J Radiat Biol Relat Stud Phys Chem Med ISSN: 0020-7616