Literature DB >> 10837935

Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality.

C C Ling1, J Humm, S Larson, H Amols, Z Fuks, S Leibel, J A Koutcher.   

Abstract

PURPOSE: The goals of this study were to survey and summarize the advances in imaging that have potential applications in radiation oncology, and to explore the concept of integrating physical and biological conformality in multidimensional conformal radiotherapy (MD-CRT). METHODS AND MATERIALS: The advances in three-dimensional conformal radiotherapy (3D-CRT) have greatly improved the physical conformality of treatment planning and delivery. The development of intensity-modulated radiotherapy (IMRT) has provided the "dose painting" or "dose sculpting" ability to further customize the delivered dose distribution. The improved capabilities of nuclear magnetic resonance imaging and spectroscopy, and of positron emission tomography, are beginning to provide physiological and functional information about the tumor and its surroundings. In addition, molecular imaging promises to reveal tumor biology at the genotype and phenotype level. These developments converge to provide significant opportunities for enhancing the success of radiotherapy.
RESULTS: The ability of IMRT to deliver nonuniform dose patterns by design brings to fore the question of how to "dose paint" and "dose sculpt", leading to the suggestion that "biological" images may be of assistance. In contrast to the conventional radiological images that primarily provide anatomical information, biological images reveal metabolic, functional, physiological, genotypic, and phenotypic data. Important for radiotherapy, the new and noninvasive imaging methods may yield three-dimensional radiobiological information. Studies are urgently needed to identify genotypes and phenotypes that affect radiosensitivity, and to devise methods to image them noninvasively. Incremental to the concept of gross, clinical, and planning target volumes (GTV, CTV, and PTV), we propose the concept of "biological target volume" (BTV) and hypothesize that BTV can be derived from biological images and that their use may incrementally improve target delineation and dose delivery. We emphasize, however, that much basic research and clinical studies are needed before this potential can be realized.
CONCLUSIONS: Whereas IMRT may have initiated the beginning of the end relative to physical conformality in radiotherapy, biological imaging may launch the beginning of a new era of biological conformality. In combination, these approaches constitute MD-CRT that may further improve the efficacy of cancer radiotherapy in the new millennium.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10837935     DOI: 10.1016/s0360-3016(00)00467-3

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  221 in total

Review 1.  From PET detectors to PET scanners.

Authors:  John L Humm; Anatoly Rosenfeld; Alberto Del Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-10-02       Impact factor: 9.236

2.  The role of molecular imaging in precision radiation therapy for target definition, treatment planning optimisation and quality control.

Authors:  Giovanni Lucignani; Barbara A Jereczek-Fossa; Roberto Orecchia
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-30       Impact factor: 9.236

3.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

4.  The impact of audio-visual biofeedback on 4D PET images: results of a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Byungchul Cho; Youngho Seo; Paul J Keall
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

5.  Recommendations for the use of PET and PET-CT for radiotherapy planning in research projects.

Authors:  E J Somer; L C Pike; P K Marsden
Journal:  Br J Radiol       Date:  2012-02-28       Impact factor: 3.039

6.  A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management.

Authors:  Michael W Kissick; Xiaohu Mo; Keisha C McCall; Leah K Schubert; David C Westerly; Thomas R Mackie
Journal:  Phys Med Biol       Date:  2010-04-30       Impact factor: 3.609

7.  Evaluation of the spatial dependence of the point spread function in 2D PET image reconstruction using LOR-OSEM.

Authors:  D Wiant; J A Gersh; M Bennett; J D Bourland
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

Review 8.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

9.  On Voxel based Iso-Tumor Control Probabilty and Iso-Complication Maps for Selective Boosting and Selective Avoidance Intensity Modulated Radiotherapy.

Authors:  Yusung Kim; Wolfgang A Tomé
Journal:  Imaging Decis (Berl)       Date:  2008

10.  Heterogeneity in intratumor correlations of 18F-FDG, 18F-FLT, and 61Cu-ATSM PET in canine sinonasal tumors.

Authors:  Tyler J Bradshaw; Stephen R Bowen; Ngoneh Jallow; Lisa J Forrest; Robert Jeraj
Journal:  J Nucl Med       Date:  2013-09-16       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.