Literature DB >> 10834152

Vortex shedding as a mechanism for free emboli formation in mechanical heart valves.

D Bluestein1, E Rambod, M Gharib.   

Abstract

The high incidence of thromboembolic complications of mechanical heart valves (MHV) limits their success as permanent implants. The thrombogenicity of all MHV is primarily due to platelet activation by contact with foreign surfaces and by nonphysiological flow patterns. The latter include elevated flow stresses and regions of recirculation of blood that are induced by valve design characteristics. A numerical simulation of unsteady turbulent flow through a bileaflet MHV was conducted, using the Wilcox k-omega turbulence model for internal low-Reynolds-number flows, and compared to quantitative flow visualization performed in a pulse duplicator system using Digital Particle Image Velocimetry (DPIV). The wake of the valve leaflet during the deceleration phase revealed an intricate pattern of interacting shed vortices. Particle paths showed that platelets that were exposed to the highest flow stresses around the leaflets were entrapped within the shed vortices. Potentially activated, such platelets may tend to aggregate and form free emboli. Once formed, such free emboli would be convected downstream by the shed vortices, increasing the risk of systemic emboli.

Entities:  

Mesh:

Year:  2000        PMID: 10834152     DOI: 10.1115/1.429634

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  25 in total

1.  Effects of myocardial contractility on microemboli production by mechanical heart valves in a bovine model.

Authors:  G Deklunder; J L Lecroart; J L Conger; D Lapeyre; I Gregoric; H Rose; D Tamez; O H Frazier
Journal:  Tex Heart Inst J       Date:  2000

2.  Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve.

Authors:  Chi-Pei Li; Po-Chien Lu
Journal:  J Artif Organs       Date:  2012-06-13       Impact factor: 1.731

3.  The effect of implantation orientation of a bileaflet mechanical heart valve on kinematics and hemodynamics in an anatomic aorta.

Authors:  Iman Borazjani; Fotis Sotiropoulos
Journal:  J Biomech Eng       Date:  2010-11       Impact factor: 2.097

4.  Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

Authors:  Yubing Shi; Tony Joon Hock Yeo; Yong Zhao; Ned H C Hwang
Journal:  J Biol Phys       Date:  2007-03-28       Impact factor: 1.365

5.  Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

Authors:  Sivakkumar Arjunon; Pablo Hidalgo Ardana; Neelakantan Saikrishnan; Shalv Madhani; Brent Foster; Ari Glezer; Ajit P Yoganathan
Journal:  J Biomech Eng       Date:  2015-02-11       Impact factor: 2.097

Review 6.  Review of numerical methods for simulation of mechanical heart valves and the potential for blood clotting.

Authors:  Mohamad Shukri Zakaria; Farzad Ismail; Masaaki Tamagawa; Ahmad Fazli Abdul Aziz; Surjatin Wiriadidjaja; Adi Azrif Basri; Kamarul Arifin Ahmad
Journal:  Med Biol Eng Comput       Date:  2017-07-26       Impact factor: 2.602

7.  Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.

Authors:  Michalis Xenos; Gaurav Girdhar; Yared Alemu; Jolyon Jesty; Marvin Slepian; Shmuel Einav; Danny Bluestein
Journal:  J Biomech       Date:  2010-05-21       Impact factor: 2.712

8.  Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD.

Authors:  Wei-Che Chiu; Gaurav Girdhar; Michalis Xenos; Yared Alemu; Jõao S Soares; Shmuel Einav; Marvin Slepian; Danny Bluestein
Journal:  J Biomech Eng       Date:  2014-02       Impact factor: 2.097

Review 9.  Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.

Authors:  Thomas E Claiborne; Marvin J Slepian; Syed Hossainy; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2012-11       Impact factor: 3.166

10.  Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.

Authors:  Danny Bluestein; Gaurav Girdhar; Shmuel Einav; Marvin J Slepian
Journal:  J Biomech       Date:  2012-12-06       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.