Literature DB >> 10832979

Long-term results of correction of high myopia with an iris claw phakic intraocular lens.

M Landesz1, J G Worst, G van Rij.   

Abstract

PURPOSE: Anterior chamber phakic intraocular lenses (PIOLs) are one of the modalities used to correct high myopia. We report the long-term results of our prospective study on the Artisan 5-mm optic myopia lens.
METHODS: We studied 67 eyes of 38 consecutive patients with preoperative myopia ranging from -5.38 to -28.00 D. All patients were operated by one surgeon. Mean follow-up was 35 months (24 months in 67 eyes and 36 months in 61 eyes).
RESULTS: In 45 eyes (67.2%), postoperative residual refraction was within +/- 1.00 D of emmetropia. The mean refraction was stable statistically during the entire follow-up period. Mean best spectacle-corrected visual acuity improved from 20/40 to 20/32. Mean endothelial cell loss at 6 months was 5.5% (range, -52.4% to +9.3%), at 12 months, 7.21% (range, -53.2% to +20.1%), at 24 months, 9.1% (range -43.6% to +13.6%), and at 36 months, 10.9% (range, -43.0O% to +11.4%). The majority of eyes had an increase in best spectacle-corrected visual acuity; 5 eyes lost best spectacle-corrected visual acuity. We encountered no major complications.
CONCLUSION: Implanting the Artisan 5-mm optic myopia lens in high myopic eyes resulted in a stable and accurate refractive outcome. The apparent progressive corneal endothelial cell loss remains a matter of concern.

Entities:  

Mesh:

Year:  2000        PMID: 10832979     DOI: 10.3928/1081-597X-20000501-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  14 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Basic knowledge of refractive surgery: correction of refractive errors using modern surgical procedures.

Authors:  Thomas Kohnen; Anja Strenger; Oliver K Klaproth
Journal:  Dtsch Arztebl Int       Date:  2008-02-29       Impact factor: 5.594

5.  Correction of high myopia with different phakic anterior chamber intraocular lenses: ICARE angle-supported lens and Verisyse iris-claw lens.

Authors:  Stanislawa Gierek-Ciaciura; Ariadna Gierek-Lapinska; Krzysztof Ochalik; Ewa Mrukwa-Kominek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-07-01       Impact factor: 3.117

6.  Artisan phakic intraocular lens for correcting high myopia.

Authors:  Tova Lifshitz; Jaime Levy; Isaac Aizenman; Itamar Klemperer; Shmuel Levinger
Journal:  Int Ophthalmol       Date:  2005-09-29       Impact factor: 2.031

7.  Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations.

Authors:  Young Min Park; Bong Joon Choi; Jong Soo Lee
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

8.  Long-term endothelial cell loss with the iris-claw intraocular phakic lenses (Artisan®).

Authors:  Virgilio Galvis; John F Villamil; María Fernanda Acuña; Paul A Camacho; Jesús Merayo-Lloves; Alejandro Tello; Sandra Lizeth Zambrano; Juan José Rey; Juan Vicente Espinoza; Angélica María Prada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-28       Impact factor: 3.117

9.  Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia.

Authors:  X Yuan; H Z Ping; W C Hong; D Yin; Z Ting
Journal:  Eye (Lond)       Date:  2011-12-02       Impact factor: 3.775

10.  Light-adjustable lens.

Authors:  Daniel M Schwartz
Journal:  Trans Am Ophthalmol Soc       Date:  2003