Literature DB >> 10831909

Complications of foldable intraocular lenses requiring explanation or secondary intervention--1998 survey.

N Mamalis1.   

Abstract

A survey of the complications associated with foldable intraocular lenses (IOLs) that required explantation or secondary intervention was sent to domestic members of the American Society of Cataract and Refractive Surgery in 1998. Preoperative data as well as patient signs and symptoms were obtained and postoperative results and outcomes assessed. The types of foldable IOLs explanted were tabulated. The percentage of each type removed and the common reasons for removal were as follows: 38%--3-piece monofocal silicone IOLs for incorrect lens power followed by dislocation/decentration; 31%--3-piece multifocal silicone IOLs for glare/optical aberrations; 16%--3-piece acrylic IOLs for glare/optical aberrations followed by incorrect lens power and dislocation; 15%--1-piece or plate-haptic silicone IOLs for dislocation/decentration followed by incorrect lens power. Visual outcomes were uniformly good in the 4 groups. Meticulous surgical technique, IOL insertion, and IOL power measurements, along with proper patient selection, are important factors in avoiding complications with foldable IOLs.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10831909     DOI: 10.1016/s0886-3350(00)00424-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  Risk of late intraocular lens dislocation after cataract surgery, 1980-2009: a population-based study.

Authors:  Sam L Pueringer; David O Hodge; Jay C Erie
Journal:  Am J Ophthalmol       Date:  2011-06-17       Impact factor: 5.258

2.  Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth.

Authors:  Haya Matuoq Al Farhan
Journal:  BMC Ophthalmol       Date:  2014-02-25       Impact factor: 2.209

3.  A simple technique of intraocular lenses explantation for single-piece foldable lenses.

Authors:  Arup Bhaumik; Santanu Mitra
Journal:  Indian J Ophthalmol       Date:  2017-12       Impact factor: 1.848

4.  Commentary: Indications and surgical techniques for intraocular lens explantation.

Authors:  Mahipal S Sachdev
Journal:  Indian J Ophthalmol       Date:  2019-08       Impact factor: 1.848

5.  Intraocular lens power calculation for plus and minus lenses in high myopia using partial coherence interferometry.

Authors:  Matthias Fuest; Niklas Plange; David Kuerten; Hannah Schellhase; Babac A E Mazinani; Peter Walter; Stephan Kohnen; Randolf A Widder; Gernot Roessler
Journal:  Int Ophthalmol       Date:  2021-02-01       Impact factor: 2.031

6.  Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices.

Authors:  Bo Yi Kim; Ikhyun Jun
Journal:  Korean J Ophthalmol       Date:  2022-06-15

7.  Reproducibility of the optical Biometer OA-1000 (Tomey).

Authors:  Susanne Christiane Goebels; Berthold Seitz; Achim Langenbucher
Journal:  Biomed Res Int       Date:  2014-04-10       Impact factor: 3.411

8.  Refractive Results Using a New Optical Biometry Device: Comparison With Ultrasound Biometry Data.

Authors:  Serdar Aktas; Hatice Aktas; Mehmet Tetikoglu; Hac Murat Sagdk; Fatih Özcura
Journal:  Medicine (Baltimore)       Date:  2015-12       Impact factor: 1.817

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.