Literature DB >> 10831863

Deformations of the isolated mouse tectorial membrane produced by oscillatory forces.

C C Abnet1, D M Freeman.   

Abstract

Mechanical properties of the isolated tectorial membrane (TM) of the mouse were measured by applying oscillatory shear forces to the TM with a magnetic bead (radius approximately 10 mcm). Sinusoidal forces at 10 Hz with amplitudes from 5 to 33 nN were applied tangentially to the surfaces of 11 TMs. The ratio of force to bead displacement ranged from 0.04 to 0.98 N/m (median: 0.18 N/m, interquartile range: 0.11-0.30 N/m, n=90). Increasing frequency from 10 to 100 Hz decreased the magnitude of the displacement of the magnetic bead by 6-7.3 dB/decade. The phase of the displacement lagged that of the stimulus current by approximately 27-44 degrees across frequencies. Displacement of the adjacent tissue decreased as the distance from the magnetic bead increased. Space constants were of the order of tens of micrometers. Forces with equal amplitude and frequency were applied radially and longitudinally. Longitudinal displacements in response to longitudinal forces were 1-10 times as large as radial displacements in response to radial forces in 85% of 560 paired measurements. These results suggest that the following mechanical properties of the TM are important. (1) Viscoelasticity: The frequency dependence of TM displacement lies between that of a purely viscous and a purely elastic material, suggesting that both are important. (2) Mechanical coupling: Space constants indicate that hair bundles could interact mechanically with adjacent hair bundles via the TM. (3) Anisotropy: The mechanical impedance is greater in the radial direction than it is in the longitudinal direction. This mechanical anisotropy correlates with anatomical anisotropies, such as the radially oriented fibrillar structure of the TM.

Entities:  

Mesh:

Year:  2000        PMID: 10831863     DOI: 10.1016/s0378-5955(00)00041-1

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  26 in total

1.  Impedance analysis of the organ of corti with magnetically actuated probes.

Authors:  Marc P Scherer; Anthony W Gummer
Journal:  Biophys J       Date:  2004-08       Impact factor: 4.033

2.  Evidence and implications of inhomogeneity in tectorial membrane elasticity.

Authors:  Brett Shoelson; Emilios K Dimitriadis; Hongxue Cai; Bechara Kachar; Richard S Chadwick
Journal:  Biophys J       Date:  2004-10       Impact factor: 4.033

3.  Mechanical responses of the organ of corti to acoustic and electrical stimulation in vitro.

Authors:  Dylan K Chan; A J Hudspeth
Journal:  Biophys J       Date:  2005-09-16       Impact factor: 4.033

4.  Measurement of the mechanical properties of isolated tectorial membrane using atomic force microscopy.

Authors:  Rachel Gueta; David Barlam; Roni Z Shneck; Itay Rousso
Journal:  Proc Natl Acad Sci U S A       Date:  2006-09-25       Impact factor: 11.205

5.  Sound-evoked deflections of outer hair cell stereocilia arise from tectorial membrane anisotropy.

Authors:  R Gueta; D Barlam; R Z Shneck; I Rousso
Journal:  Biophys J       Date:  2008-02-29       Impact factor: 4.033

6.  Tectorial membrane stiffness gradients.

Authors:  Claus-Peter Richter; Gulam Emadi; Geoffrey Getnick; Alicia Quesnel; Peter Dallos
Journal:  Biophys J       Date:  2007-05-11       Impact factor: 4.033

7.  Col11a2 deletion reveals the molecular basis for tectorial membrane mechanical anisotropy.

Authors:  Kinuko Masaki; Jianwen Wendy Gu; Roozbeh Ghaffari; Gary Chan; Richard J H Smith; Dennis M Freeman; A J Aranyosi
Journal:  Biophys J       Date:  2009-06-03       Impact factor: 4.033

8.  Theoretical conditions for high-frequency hair bundle oscillations in auditory hair cells.

Authors:  Jong-Hoon Nam; Robert Fettiplace
Journal:  Biophys J       Date:  2008-08-01       Impact factor: 4.033

9.  The effect of tectorial membrane and basilar membrane longitudinal coupling in cochlear mechanics.

Authors:  Julien Meaud; Karl Grosh
Journal:  J Acoust Soc Am       Date:  2010-03       Impact factor: 1.840

10.  Frequency-dependent shear impedance of the tectorial membrane.

Authors:  Jianwen Wendy Gu; Werner Hemmert; Dennis M Freeman; A J Aranyosi
Journal:  Biophys J       Date:  2008-05-30       Impact factor: 4.033

View more