Literature DB >> 10830523

Assessment of left ventricular function by gated myocardial perfusion and gated blood-pool SPECT: can we use the same reference database?

A K Paul1, S Hasegawa, J Yoshioka, H Yamaguchi, E Tsujimura, T Nishimura.   

Abstract

The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m-tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8 +/- 3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8 +/- 10.5 ml [95% confidence interval (CI): -8.6 +/- 3.0 ml], 2.6 +/- 7.3 ml (CI: -1.4 +/- 6.6 ml) and -2.3 +/- 5.1% (CI: -5.1 +/- 0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10830523     DOI: 10.1007/bf02988584

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  2 in total

1.  Gated single photon emission tomography MIBI stress perfusion imaging for assessing cardiac output and index in obese and non-obese patients.

Authors:  J P Coffey; J C Hill
Journal:  Ir J Med Sci       Date:  2007-11-20       Impact factor: 1.568

2.  Assessment of left ventricular diastolic function by gated single-photon emission tomography: comparison with Doppler echocardiography.

Authors:  Tetsuhiro Yamano; Tomoki Nakamura; Kenzo Sakamoto; Takato Hikosaka; Kan Zen; Takeshi Nakamura; Takahisa Sawada; Akihiro Azuma; Tsunehiko Nishimura; Masao Nakagawa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-08-21       Impact factor: 9.236

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.